Publicação: Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode
dc.contributor.author | Bergamini, Marcio F. | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:21:04Z | |
dc.date.available | 2014-05-20T15:21:04Z | |
dc.date.issued | 2006-08-01 | |
dc.description.abstract | This work describes an electroanalytical method for determining gold(I) thiomalate, aurothiomalate, widely used for treatment of reumatoid arthiritis, using a screen-printed carbon electrode (SPCE). Aurothiomalate (AuTM) was determined indirectly at the same electrode by accumulating it first at -1.5 V vs. printed carbon. At this potential in the adsorbed state, the AuTM is reduced to Au(0), which is then oxidized at two steps at -0.22 V and +0.54 V on SPCE. Using optimized conditions of 60 s deposition time, -1.5 V (vs. printed carbon) accumulation potential, 100 mV s(-1) scan rate, linear calibration graphs can be obtained by monitoring the peak at +0.54 V for AuTM in HCl 0.1 mol L-1 from 1.43 x 10(-6) to 1.55 x 10(-4) mol L-1. A limit of detection obtained was 6.50 x 10(-7) mol L-1, and the relative standard deviation from five measurements of 3.0 x 10(-5) mol L-1 AuTM is 4.5%. The method was successfully applied for AuTM determination in human urine sample. | en |
dc.description.affiliation | UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 1457-1462 | |
dc.identifier | http://dx.doi.org/10.1002/elan.200603534 | |
dc.identifier.citation | Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 18, n. 15, p. 1457-1462, 2006. | |
dc.identifier.doi | 10.1002/elan.200603534 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/32246 | |
dc.identifier.wos | WOS:000239719800003 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Electroanalysis | |
dc.relation.ispartofjcr | 2.851 | |
dc.relation.ispartofsjr | 0,692 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | sodium aurothiomalate | pt |
dc.subject | gold(I) thiolate determination | pt |
dc.subject | screen-printed electrode | pt |
dc.subject | gold-base drugs | pt |
dc.title | Anodic stripping voltammetric determination of aurothiomalate in urine using a screen-printed carbon electrode | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-Blackwell | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: