Wavelet-artificial immune system algorithm applied to voltage disturbance diagnosis in electrical distribution systems

dc.contributor.authorLima, Fernando P.A. [UNESP]
dc.contributor.authorLotufo, Anna Diva P. [UNESP]
dc.contributor.authorMinussi, Carlos Roberto [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:57:59Z
dc.date.available2018-12-11T16:57:59Z
dc.date.issued2015-01-01
dc.description.abstractThis study presents a new approach to detecting and classifying voltage disturbances in electrical distribution systems based on wavelet transform and artificial immune algorithm. This proposal unifies the negative selection artificial immune algorithm with the discrete wavelet transform concept. Thus, the measurements obtained in a distribution substation by the supervisory control and data acquisition acquisition system are transformed into the wavelet domain. Afterward, a negative selection artificial immune system realises the diagnosis, identifying and classifying the abnormalities. The principal application of this tool is to aid the system operation during faults as well as to supervise the protection system. To evaluate the performance of the proposed method, two distribution systems were modelled in EMTP software: an 84-bus test system and a 134-bus real system. The results show a good performance, emphasising the precision of the diagnosis.en
dc.description.affiliationElectrical Engineering Department, Faculty of Engineering of Ilha Solteira, UNESP, Universidade Estadual Paulista 'Júlio de Mesquita Filho', Av. Brasil 56, P.O. Box 31
dc.description.affiliationUnespElectrical Engineering Department, Faculty of Engineering of Ilha Solteira, UNESP, Universidade Estadual Paulista 'Júlio de Mesquita Filho', Av. Brasil 56, P.O. Box 31
dc.format.extent1104-1111
dc.identifierhttp://dx.doi.org/10.1049/iet-gtd.2014.1102
dc.identifier.citationIET Generation, Transmission and Distribution, v. 9, n. 11, p. 1104-1111, 2015.
dc.identifier.doi10.1049/iet-gtd.2014.1102
dc.identifier.file2-s2.0-84938567285.pdf
dc.identifier.issn1751-8687
dc.identifier.scopus2-s2.0-84938567285
dc.identifier.urihttp://hdl.handle.net/11449/171977
dc.language.isoeng
dc.relation.ispartofIET Generation, Transmission and Distribution
dc.relation.ispartofsjr0,907
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.titleWavelet-artificial immune system algorithm applied to voltage disturbance diagnosis in electrical distribution systemsen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6022112355517660[2]
unesp.author.lattes7166279400544764[3]
unesp.author.orcid0000-0002-0192-2651[2]
unesp.author.orcid0000-0001-6428-4506[3]
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
2-s2.0-84938567285.pdf
Tamanho:
757.57 KB
Formato:
Adobe Portable Document Format
Descrição: