dc.description.abstractMonitoring, fault detection, and diagnosis of electric induction motors are becoming increasingly important in the field of electrical machines as new data-processing techniques and methods for analyzing the motor stator current. Special attention has been devoted to noninvasive methods capable of detecting faults using measured data without requiring motor disassembly and its structural parts. Some enterprises such as Mining, Petroleum and Water and Sewage Treatment process uses induction motor of large power flow, what are installed at remote sites. The electrical and mechanical failures of such motors often disrupt productivity and require maintenance. Currently the containment of maintenance costs, these remote sites work without the presence of a service technician. A fuzzy logic approach may help to diagnose induction motor faults at these sites and to transmit the fault diagnosis (via 3G technology) to maintenance central or a cell phone programmed. The contribution of this paper is the use of fuzzy logic for the automated practical detection of broken bars in induction motors in remote locations without the presence of an experienced technician.en
dc.description.affiliationIFSP Fed Inst Educ, Electrotech Engn, BR-01109010 Sao Paulo, SP, Brazil
dc.description.affiliationUNESP Univ Estadual Paulista, Mech Engn, BR-12516410 Sao Paulo, SP, Brazil
dc.description.affiliationUnespUNESP Univ Estadual Paulista, Mech Engn, BR-12516410 Sao Paulo, SP, Brazil
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.format.extent8
dc.identifier.citationProceedings Of The 22nd International Congress On Sound And Vibration. Auburn: Int Inst Acoustics & Vibration, 8 p., 2015.
dc.identifier.lattes9074899537066812
dc.identifier.urihttp://hdl.handle.net/11449/162687
dc.identifier.wosWOS:000398997005009
dc.language.isoeng
dc.publisherInt Inst Acoustics & Vibration
dc.relation.ispartofProceedings Of The 22nd International Congress On Sound And Vibration
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.titleA FUZZY LOGIC APPROACH TO DIAGNOSE INDUCTION MOTOR FAULTS IN REMOTE SITE BY CELL PHONEen
dc.typeTrabalho apresentado em evento
dcterms.rightsHolderInt Inst Acoustics & Vibration
dspace.entity.typePublication
unesp.author.lattes9074899537066812
unesp.departmentEngenharia Mecânica - FEGpt

Arquivos