Publicação: Technology assessment for power quality mitigation devices - Micro-DVR case study
dc.contributor.author | Vairamohan, B. | |
dc.contributor.author | Komatsu, W. | |
dc.contributor.author | Galassi, M. | |
dc.contributor.author | Monteiro, T. C. | |
dc.contributor.author | Oliveira, M. A. | |
dc.contributor.author | Ami, S. U. | |
dc.contributor.author | Matakas, L. | |
dc.contributor.author | Marafão, F. P. [UNESP] | |
dc.contributor.author | Bormio, E. | |
dc.contributor.author | Camargo, J. | |
dc.contributor.author | McGranaghan, M. F. | |
dc.contributor.author | Jardini, J. A. | |
dc.contributor.institution | Electrical Power Research Institute (EPRI) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Companhia Paulista de Força e Luz (CPFL Piratininga) | |
dc.contributor.institution | Expertise Engenharia Ltd. | |
dc.date.accessioned | 2014-05-27T11:23:50Z | |
dc.date.available | 2014-05-27T11:23:50Z | |
dc.date.issued | 2008-12-23 | |
dc.description.abstract | This work presents a case study on technology assessment for power quality devices. A system compatibility test protocol for power quality mitigation devices was developed in order to evaluate the functionality of three-phase voltage restoration devices. In order to case test this test protocol, a development platform with reduced power for DVR (Dynamic Voltage Restorer), the Micro-DVR, was tested, and results were discussed based on voltage disturbances standards. ©2008 IEEE. | en |
dc.description.affiliation | Electrical Power Research Institute (EPRI), Knoxville, TN | |
dc.description.affiliation | Escola Politécnica da Universidade de Sao Paulo (EPUSP), Sao Paulo, SP | |
dc.description.affiliation | Paulista State University (UNESP), Sorocaba, SP | |
dc.description.affiliation | Companhia Paulista de Força e Luz (CPFL Piratininga), Campinas, SP | |
dc.description.affiliation | Expertise Engenharia Ltd., Campinas, SP | |
dc.description.affiliationUnesp | Paulista State University (UNESP), Sorocaba, SP | |
dc.identifier | http://dx.doi.org/10.1109/ICHQP.2008.4668799 | |
dc.identifier.citation | ICHQP 2008: 13th International Conference on Harmonics and Quality of Power. | |
dc.identifier.doi | 10.1109/ICHQP.2008.4668799 | |
dc.identifier.scopus | 2-s2.0-57749091443 | |
dc.identifier.uri | http://hdl.handle.net/11449/70870 | |
dc.language.iso | eng | |
dc.relation.ispartof | ICHQP 2008: 13th International Conference on Harmonics and Quality of Power | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | Dynamic voltage restorer | |
dc.subject | Power euality mitigation devices | |
dc.subject | Voltage sags | |
dc.subject | Voltage swells | |
dc.subject | Electric measuring instruments | |
dc.subject | Power quality | |
dc.subject | Standardization | |
dc.subject | Technological forecasting | |
dc.subject | Videodisks | |
dc.subject | Voltage regulators | |
dc.subject | Voltage stabilizing circuits | |
dc.subject | Case studies | |
dc.subject | Development platforms | |
dc.subject | Phase voltages | |
dc.subject | Power quality devices | |
dc.subject | Power quality mitigations | |
dc.subject | System compatibilities | |
dc.subject | Technology assessments | |
dc.subject | Test protocols | |
dc.subject | Voltage disturbances | |
dc.subject | Electronic equipment testing | |
dc.title | Technology assessment for power quality mitigation devices - Micro-DVR case study | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, Sorocaba | pt |
unesp.department | Engenharia de Controle e Automação - ICTS | pt |