Publicação: Determination of Ethambutol in Aqueous Medium Using an Inexpensive Gold Microelectrode Array as Amperometric Sensor
dc.contributor.author | Lima, A. E. B. | |
dc.contributor.author | Luz, G. E. | |
dc.contributor.author | Batista, N. C. | |
dc.contributor.author | Longo, E. [UNESP] | |
dc.contributor.author | Cavalcante, L. S. | |
dc.contributor.author | Santos, R. S. | |
dc.contributor.institution | Univ Estadual Piaui | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2018-11-27T16:55:46Z | |
dc.date.available | 2018-11-27T16:55:46Z | |
dc.date.issued | 2016-05-01 | |
dc.description.abstract | In this paper, gold microelectrode array (Au-MEA) were employed to determination of ethambutol in aqueous medium. Au-MEA was constructed with an electronic microchip integrated circuit. The standard curve (analytical curve) was constructed for a single microelectrode (ME) in a concentration range of 5.0 x 10(-5) to 2.0 x 10(-3) molL(-1), allowing estimation of both the limit of detection (LOD) (4.73 x 10(-5) molL(-1)) and the limit of quantification (LOQ) (1.57 x 10(-4) molL(-1)) for ethambutol. When the MEA was utilized, the LOD and LOQ were 1.55 x 10(-7) and 5.18 x 10(-7) molL(-1), respectively. Our results indicated that Au-MEA can be utilized as amperometric sensors for ethambutol determination in aqueous | en |
dc.description.affiliation | Univ Estadual Piaui, DQ, GERATEC, PPGQ, Rua Joao Cabral 2231,POB 381, BR-64002150 Teresina, PI, Brazil | |
dc.description.affiliation | Univ Estadual Paulista, CDMF, POB 355, BR-14801907 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, CDMF, POB 355, BR-14801907 Araraquara, SP, Brazil | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | FINEP | |
dc.description.sponsorshipId | FINEP: 0315/08 | |
dc.format.extent | 985-989 | |
dc.identifier | http://dx.doi.org/10.1002/elan.201500600 | |
dc.identifier.citation | Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 28, n. 5, p. 985-989, 2016. | |
dc.identifier.doi | 10.1002/elan.201500600 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.uri | http://hdl.handle.net/11449/165221 | |
dc.identifier.wos | WOS:000379040500010 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Electroanalysis | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Amperometric Sensor | |
dc.subject | Gold microelectrode array | |
dc.subject | Ethambutol | |
dc.title | Determination of Ethambutol in Aqueous Medium Using an Inexpensive Gold Microelectrode Array as Amperometric Sensor | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-Blackwell | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Bioquímica e Tecnologia - IQ | pt |