Logotipo do repositório
 

Publicação:
Direct Analysis of Doping Agents in Raw Urine Using Hydrophobic Paper Spray Mass Spectrometry

dc.contributor.authorRossini, Eduardo Luiz [UNESP]
dc.contributor.authorKulyk, Dmytro S.
dc.contributor.authorAnsu-Gyeabourh, Emelia
dc.contributor.authorSahraeian, Taghi
dc.contributor.authorPezza, Helena Redigolo [UNESP]
dc.contributor.authorBadu-Tawiah, Abraham K.
dc.contributor.institutionOhio State University
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2020-12-12T02:09:36Z
dc.date.available2020-12-12T02:09:36Z
dc.date.issued2020-06-03
dc.description.abstractIn this study, the direct analysis of doping agents in urine samples with no sample preparation by a modified paper spray mass spectrometry (PS-MS) methodology has been demonstrated for the first time. We have described a paper surface treatment with trichloromethylsilane using a gas-phase reaction to increase the ionization of target compounds. This approach was applied for the analysis of two classes of banned substances in urine samples: anabolic agents (trenbolone and clenbuterol) and diuretics (furosemide and hydrochlorothiazide). Under optimized conditions, the developed methods presented satisfactory repeatability, and an analysis of variance showed linearity without lack-of-fit. Highly sensitive detections as low as sub-nanogram per milliliter levels, which is below the minimum required performance levels proposed by the World Anti-Doping Agency, have been reached using the hydrophobic PS-MS analysis without any preconcentration and cleanup step.en
dc.description.affiliationDepartment of Chemistry and Biochemistry Ohio State University, 100 West 18th Avenue
dc.description.affiliationInstitute of Chemistry Department of Analytical Chemistry São Paulo State University (UNESP), Rua Professor Francisco Degni 55 ,P.O. Box 355
dc.description.affiliationUnespInstitute of Chemistry Department of Analytical Chemistry São Paulo State University (UNESP), Rua Professor Francisco Degni 55 ,P.O. Box 355
dc.format.extent1212-1222
dc.identifierhttp://dx.doi.org/10.1021/jasms.0c00063
dc.identifier.citationJournal of the American Society for Mass Spectrometry, v. 31, n. 6, p. 1212-1222, 2020.
dc.identifier.doi10.1021/jasms.0c00063
dc.identifier.issn1879-1123
dc.identifier.scopus2-s2.0-85085904338
dc.identifier.urihttp://hdl.handle.net/11449/200553
dc.language.isoeng
dc.relation.ispartofJournal of the American Society for Mass Spectrometry
dc.sourceScopus
dc.subjectanabolic agent
dc.subjectanalytical methods
dc.subjectdiuretic
dc.subjectdoping
dc.subjectpaper modification
dc.subjectpaper spray ionization
dc.titleDirect Analysis of Doping Agents in Raw Urine Using Hydrophobic Paper Spray Mass Spectrometryen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.orcid0000-0001-8642-3431[6]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos