Publicação: Evaluation of Ir and Pd(NO3)2/Mg(NO3) 2 as modifiers for the simultaneous determination of Mn, Ni, Pb, and Sb in fuel ethanol by graphite furnace AAS
dc.contributor.author | Neves, Denise Regina [UNESP] | |
dc.contributor.author | Oliveira, Silvana Ruella [UNESP] | |
dc.contributor.author | Rêgo, Jardes Figuerêdo Do [UNESP] | |
dc.contributor.author | Flumignan, Ddjkilo Luiz [UNESP] | |
dc.contributor.author | Oliveira, José Eduardo [UNESP] | |
dc.contributor.author | Neto, José Anchieta Gomes [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (UNESP) | |
dc.date.accessioned | 2022-04-29T08:48:18Z | |
dc.date.available | 2022-04-29T08:48:18Z | |
dc.date.issued | 2010-07-01 | |
dc.description.abstract | The mixture Pd(NO3)2/ Mg(NO3)2 and an Ir-coated platform co-injected with Pd(NO3)2/ Mg(NO3)2 were evaluated as modifiers for the direct and simultaneous determination of Mn, Ni, Pb, and Sb in fuel ethanol by graphite furnace atomic absorption spectrometry. For a 20-μL diluted sample dispensed onto the platform of graphite tube in the presence of 5 μg Pd and 3 μg Mg, analytical curves in the 0 - 50.0 Mg L-1 range were built up resulting in linear correlation coefficients better than 0.99. The calculated characteristic masses were 6 pg Mn, 25 pg Ni, 67 pg Pb, and 50 pg Sb. The limits of detection (LOD) were 0.13 Mg L' Mn, 1.2 pg L-1 Ni, 1.2 Mg L' Pb, and 0.10 Mg L-1 Sb. Accuracy was checked after the analysis of 10 commercial fuel ethanol samples. The results were in agreement at a 95% confidence level (paired Mest) with those obtained by inductively coupled plasma mass spectrometry. The recovery of Mn, Ni, Pb, and Sb in fuel ethanol samples was within the 97-104%, 86-116%, 83-119%, and 92-104% intervals, respectively, and the relative standard deviation (n = 12) was typically 4%, 7%, 6%, and 5%, respectively. The useful lifetime of the THGA atomizer was around 300 firings. | en |
dc.description.affiliation | UNESP Univ Estadual Paulista Institute of Chemistry, P.O. Box 355, 14801-970, Araraquara - SP | |
dc.description.affiliationUnesp | UNESP Univ Estadual Paulista Institute of Chemistry, P.O. Box 355, 14801-970, Araraquara - SP | |
dc.format.extent | 141-146 | |
dc.identifier.citation | Atomic Spectroscopy, v. 31, n. 4, p. 141-146, 2010. | |
dc.identifier.issn | 0195-5373 | |
dc.identifier.scopus | 2-s2.0-77956956138 | |
dc.identifier.uri | http://hdl.handle.net/11449/231945 | |
dc.language.iso | eng | |
dc.relation.ispartof | Atomic Spectroscopy | |
dc.source | Scopus | |
dc.title | Evaluation of Ir and Pd(NO3)2/Mg(NO3) 2 as modifiers for the simultaneous determination of Mn, Ni, Pb, and Sb in fuel ethanol by graphite furnace AAS | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |