Efficiency and Energy Consumption of Partial Carbonation Process for CO2 Capture from Natural Gas Combustion

dc.contributor.authorToledo, Rubens Coutinho [UNESP]
dc.contributor.authorde Moraes, Caio Leandro [UNESP]
dc.contributor.authorThangarasu, Vinoth
dc.contributor.authorde Carvalho, João Andrade [UNESP]
dc.contributor.authorAvila, Ivonete [UNESP]
dc.date.accessioned2026-07-16T18:41:55Z
dc.date.issued2025-04-29
dc.description.abstractBrazil has set a goal to reduce greenhouse gas (GHG) emissions, which is a significant opportunity to leverage calcium looping (CaL) technology for energy generation in natural gas power plants. CaL is a promising technology, due to sorbent low cost and availability, but its industrial implementation performance decay is a major challenge to face. While evaluating carbon-capture technologies, net emissions perspective is essential, and optimizing CaL capture through a partial carbonation cycle is a promising approach, both to reduce net emissions and improve the number of cycles before deactivation. In this context, a Brazilian dolomite was characterized and evaluated, to be used as sorbent in a CaL process employed in natural gas power plants. For such a purpose, a novel methodology has been proposed to evaluate the mass ratio of CO2 captured, to assess the energy consumed in the process. A rotatable central composite design (RCCD) model was used to identify the optimal temperature and residence time conditions in the carbonation stage of the CaL process, focusing on achieving energy efficiency. The five most promising conditions were then tested across 10 calcination–carbonation cycles, to examine the impact of partial carbonation in capture efficiency over extended cycles. The results indicate that temperature plays a critical role in the process, particularly in terms of capture efficiency, while residence time significantly affects energy consumption. The conditions that demonstrated optimal performance for both the single and the multi-cycle tests were 580 °C for 7.5 min and 550 °C for 10 min, given that index of capture efficiency (IEC10,c) values of 1.34 and 1.20 were found, respectively—up to 40% higher than at 475 °C. There was lower energy expenditure at 580 °C (Esp) (33.48 kJ), 550 °C (Esp = 37.97 kJ), CO2 mass captured (CO2cap = 9.80 mg), and the samples exhibited a more preserved surface, thus making it the most suitable option for scale-up applications.
dc.description.affiliationLC3—Laboratory of Combustion and Carbon Capture, Department of Chemistry and Energy, School of Engineering and Science, UNESP—São Paulo State University, Guaratingueta 12516-410, SP, Brazil;, caio.leandro-moraes@unesp.br, (C.L.d.M.);, ja.carvalho@unesp.br, (J.A.d.C.J.);, ivonete.avila@unesp.br, (I.A.)
dc.description.affiliationIndian Rubber Materials Research Institute, DPIIT, Ministry of Commerce and Industry, Thane 400604, Maharashtra, India;, vinoth.thangarasu@irmra.org
dc.description.affiliationUnespLC3—Laboratory of Combustion and Carbon Capture, Department of Chemistry and Energy, School of Engineering and Science, UNESP—São Paulo State University, Guaratingueta 12516-410, SP, Brazil;, caio.leandro-moraes@unesp.br, (C.L.d.M.);, ja.carvalho@unesp.br, (J.A.d.C.J.);, ivonete.avila@unesp.br, (I.A.)
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1188276955
dc.identifier.dimensionspub.1188276955
dc.identifier.doi10.3390/en18092285
dc.identifier.issn1996-1073
dc.identifier.orcid0000-0002-9682-3102
dc.identifier.orcid0009-0003-8285-6434
dc.identifier.orcid0000-0002-4658-7447
dc.identifier.orcid0000-0002-9129-0087
dc.identifier.urihttps://hdl.handle.net/11449/328026
dc.publisherMDPI
dc.relation.ispartofEnergies; n. 9; v. 18; p. 2285
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgold
dc.sourceDimensions
dc.titleEfficiency and Energy Consumption of Partial Carbonation Process for CO2 Capture from Natural Gas Combustion
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationa4071986-4355-47c3-a5a3-bd4d1a966e4f
relation.isOrgUnitOfPublication.latestForDiscoverya4071986-4355-47c3-a5a3-bd4d1a966e4f
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia e Ciências, Guaratinguetápt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
energies-18-02285.pdf
Tamanho:
2,64 MB
Formato:
Adobe Portable Document Format