Logo do repositório
 

Label-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancy

dc.contributor.authorLehr, Joshua
dc.contributor.authorBedatty Fernandes, Flavio C. [UNESP]
dc.contributor.authorBueno, Paulo Roberto [UNESP]
dc.contributor.authorDavis, Jason J.
dc.contributor.institutionUniv Oxford
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-12-03T13:11:27Z
dc.date.available2014-12-03T13:11:27Z
dc.date.issued2014-03-04
dc.description.abstractAn electrode surface confined redox group contributes to a substantial potential-dependent interfacial charging that can be sensitively probed and frequency-resolved by impedance-derived capacitance spectroscopy. In utilizing the sensitivity of this charging fingerprint to redox group environment, one can seek to generate derived sensory configurations. Exemplified here through the generation of mixed molecular films comprising ferrocene and antibody receptors to two clinically important targets, the label-free methodology is able to report on human prostatic acid phosphatase (PAP), a tumor marker, with a limit of detection of 11 pM and C-reactive protein with a limit of detection of 28 pM. Both assays exhibit linear ranges encompassing those of clinical value.en
dc.description.affiliationUniv Oxford, Dept Chem, Oxford OX1 3QZ, England
dc.description.affiliationSao Paulo State Univ, Univ Estadual Paulista, Inst Chem, Dept Phys Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Univ Estadual Paulista, Inst Chem, Dept Phys Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.format.extent2559-2564
dc.identifierhttp://dx.doi.org/10.1021/ac403727h
dc.identifier.citationAnalytical Chemistry. Washington: Amer Chemical Soc, v. 86, n. 5, p. 2559-2564, 2014.
dc.identifier.doi10.1021/ac403727h
dc.identifier.issn0003-2700
dc.identifier.lattes0477045906733254
dc.identifier.orcid0000-0003-2827-0208
dc.identifier.urihttp://hdl.handle.net/11449/113164
dc.identifier.wosWOS:000332494100040
dc.language.isoeng
dc.publisherAmer Chemical Soc
dc.relation.ispartofAnalytical Chemistry
dc.relation.ispartofjcr6.042
dc.relation.ispartofsjr2,362
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.titleLabel-free Capacitive Diagnostics: Exploiting Local Redox Probe State Occupancyen
dc.typeArtigopt
dcterms.rightsHolderAmer Chemical Soc
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.author.lattes0477045906733254[3]
unesp.author.orcid0000-0003-2827-0208[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentFísico-Química - IQARpt

Arquivos