Logotipo do repositório

Assessment of anaerobic power of swimmers: the correlation of laboratory tests on an arm ergometer with field tests in a swimming fool

dc.contributor.authorGuglielmo, LGA
dc.contributor.authorDenadai, B. S.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:26:46Z
dc.date.available2014-05-20T15:26:46Z
dc.date.issued2000-11-01
dc.description.abstractThe aim of this study was to verify the correlation between the Wingate arm crank test outputs (peak power, mean power, and fatigue index), obtained on a specific ergometer, and the performance in crawl stroke swim sprints of 14, 25, 50, and 400 m. The experiment was conducted with 9 healthy male volunteers (18.1 +/- 2.2 years of age; 172 +/- 0.04 cm; 67.7 +/- 5.92 kg and 15.7 +/- 4.57% body fat). on determined days, all individuals were submitted to the Wingate arm crank test and crawl freestyle sprints of 14, 25, 50, and 400 m as they were timed with a stopwatch. The peak power, the mean power, and the fatigue index, which were obtained during the Wingate arm crank test, were not significantly correlated with the maximum swim velocities during the crawl free-style tests of 14 (r = 0.40; r = 0.64; r = 0.11), 25 (r = 0.28; r = 0.39; r = -0.27), 50 (r = 0.03; r = 0.09; r = -0.31), and 400 (r = -0.52; r = -0.37; r = -0.65) m respectively. Thus, it is possible to conclude that the Wingate arm crank test is not suitable to assess the anaerobic power of swimmers under the described experimental conditions.en
dc.description.affiliationUniv Estadual Paulista, Dept Phys Educ, Human Performance Lab, São Paulo, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Phys Educ, Human Performance Lab, São Paulo, Brazil
dc.format.extent395-398
dc.identifierhttp://journals.lww.com/nsca-jscr/Abstract/2000/11000/Assessment_of_Anaerobic_Power_of_Swimmers__The.5.aspx
dc.identifier.citationJournal of Strength and Conditioning Research. Lawrence: Allen Press Inc., v. 14, n. 4, p. 395-398, 2000.
dc.identifier.dimensionspub.1067603264
dc.identifier.doi10.1519/1533-4287(2000)014<0395:AOAPOS>2.0.CO;2
dc.identifier.issn1064-8011
dc.identifier.issn1533-4287
dc.identifier.lattes1907479250833033
dc.identifier.orcid0000-0003-0775-1889
dc.identifier.urihttp://hdl.handle.net/11449/36853
dc.identifier.wosWOS:000165457400005
dc.language.isoeng
dc.publisherAllen Press Inc
dc.publisherWolters Kluwer
dc.relation.ispartofJournal of Strength and Conditioning Research
dc.relation.ispartofjcr2.325
dc.relation.ispartofsjr1,366
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.sourceDimensions
dc.subjectswimmerspt
dc.subjectWingatept
dc.subjectarmpt
dc.subjectpowerpt
dc.subjectanaerobicpt
dc.titleAssessment of anaerobic power of swimmers: the correlation of laboratory tests on an arm ergometer with field tests in a swimming foolen
dc.typeArtigopt
dcterms.licensehttp://edmgr.ovid.com/jscr/accounts/ifauth.htm
dcterms.rightsHolderAllen Press Inc
dspace.entity.typePublication
relation.isOrgUnitOfPublicationeecebc66-0524-4365-8462-6103e1c979de
relation.isOrgUnitOfPublication.latestForDiscoveryeecebc66-0524-4365-8462-6103e1c979de
unesp.author.lattes1907479250833033
unesp.author.orcid0000-0003-0775-1889[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Rio Claropt
unesp.departmentEducação Física - IBpt

Arquivos