VSSI (X)over-bar charts with sampling at fixed times
Loading...
Files
External sources
External sources
Date
Authors
Advisor
Coadvisor
Graduate program
Undergraduate course
Journal Title
Journal ISSN
Volume Title
Publisher
Marcel Dekker Inc
Type
Article
Access right
Acesso restrito
Files
External sources
External sources
Abstract
A standard (X) over bar chart for controlling the process mean takes samples of size no at specified, equally-spaced, fixed-time points. This article proposes a modification of the standard (X) over bar chart that allows one to take additional samples, bigger than no, between these fixed times. The additional samples are taken from the process when there is evidence that the process mean moved from target. Following the notation proposed by Reynolds (1996a) and Costs (1997) we shortly call the proposed (X) over bar chart as VSSIFT (X) over bar chart: where VSSIFT means variable sample size and sampling intervals with fixed times. The (X) over bar chart with the VSSIFT feature is easier to be administered than a standard VSSI (X) over bar chart that is not constrained to sample at the specified fixed times. The performances of the charts in detecting process mean shifts are comparable.
Description
Keywords
average time to signal, (X)over-bar control charts, statistical process control, variable sample size, variable sampling interval
Language
English
Citation
Communications In Statistics-theory and Methods. New York: Marcel Dekker Inc., v. 27, n. 11, p. 2853-2869, 1998.