Publicação: Selective Power Conditioning in Two-Phase Three-Wire Systems Based on the Conservative Power Theory
dc.contributor.author | Alonso, Augusto | |
dc.contributor.author | Paredes, Helmo K. M. [UNESP] | |
dc.contributor.author | Jose, A. O. Filho [UNESP] | |
dc.contributor.author | Bonaldo, Jakson P. | |
dc.contributor.author | Brandao, Danilo | |
dc.contributor.author | Marafao, Fernando P. [UNESP] | |
dc.contributor.author | IEEE | |
dc.contributor.institution | Norwegian Univ Sci & Technol NTNU | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de Mato Grosso do Sul (UFMS) | |
dc.contributor.institution | Universidade Federal de Minas Gerais (UFMG) | |
dc.date.accessioned | 2020-12-11T13:01:21Z | |
dc.date.available | 2020-12-11T13:01:21Z | |
dc.date.issued | 2019-01-01 | |
dc.description.abstract | AC power conditioners in electric power systems have been extensively explored in the literature based on approaches mainly focused on single- and three-phase wiring topologies, remaining a significant gap in regard to applications suitable for two-phase three-wire circuitry. Therefore, this work demonstrates that the Conservative Power Theory can be employed to generate the proper reference signals for an active power filter in two-phase three-wire networks. This methodology allows to selectively synthesize reference signals in a flexible manner, providing reactive power compensation, mitigation of unbalance and harmonic currents, as well as contributing to the reduction of neutral current at point of common coupling. The proposed strategy, its implementation, and the control design of a three-leg active power filter are discussed in this paper through simulation results, demonstrating the particularities and advantages of this approach. | en |
dc.description.affiliation | Norwegian Univ Sci & Technol NTNU, Dept Elect Power Engn, N-7491 Trondheim, Norway | |
dc.description.affiliation | Sao Paulo State Univ UNESP, GASI, BR-18087180 Sorocaba, Brazil | |
dc.description.affiliation | Fed Univ Mato Grosso UFMT, Dept Elect Engn, BR-78060900 Cuiaba, Brazil | |
dc.description.affiliation | Fed Univ Minas Gerais UFMG, Grad Prog Elect Engn, BR-31270901 Belo Horizonte, MG, Brazil | |
dc.description.affiliationUnesp | Sao Paulo State Univ UNESP, GASI, BR-18087180 Sorocaba, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Research Council of Norway | |
dc.description.sponsorshipId | FAPESP: 2018/22172-1 | |
dc.description.sponsorshipId | FAPESP: 2017/246528 | |
dc.description.sponsorshipId | FAPESP: 2017/22629-9 | |
dc.description.sponsorshipId | FAPESP: 2017/20987-5 | |
dc.description.sponsorshipId | FAPESP: 2016/08645-9 | |
dc.description.sponsorshipId | Research Council of Norway: f261735/H30 | |
dc.format.extent | 6 | |
dc.identifier.citation | 2019 Ieee Industry Applications Society Annual Meeting. New York: Ieee, 6 p., 2019. | |
dc.identifier.issn | 0197-2618 | |
dc.identifier.uri | http://hdl.handle.net/11449/197712 | |
dc.identifier.wos | WOS:000521115900011 | |
dc.language.iso | eng | |
dc.publisher | Ieee | |
dc.relation.ispartof | 2019 Ieee Industry Applications Society Annual Meeting | |
dc.source | Web of Science | |
dc.subject | Active Power Filter | |
dc.subject | Conservative Power Theory | |
dc.subject | Harmonics | |
dc.subject | Power Quality | |
dc.subject | Two-phase Three-wire | |
dc.subject | Unbalance | |
dc.title | Selective Power Conditioning in Two-Phase Three-Wire Systems Based on the Conservative Power Theory | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dcterms.rightsHolder | Ieee | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, Sorocaba | pt |
unesp.department | Engenharia de Controle e Automação - ICTS | pt |