Logotipo do repositório
 

Publicação:
Spectrophotometric determination of phosphite in fertilizers in a flow injection system with online sample preparation

dc.contributor.authorNeto, JAG
dc.contributor.authorIto, H. A.
dc.contributor.authorFernandes, K. D.
dc.contributor.authorde Moraes, M.
dc.contributor.authorCardoso, Arnaldo Alves [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:25:24Z
dc.date.available2014-05-20T15:25:24Z
dc.date.issued2000-12-01
dc.description.abstractA flow injection system with online sample preparation is proposed for the determination of phosphite in liquid fertilizers by spectrophotometry. After loop-based injection, phosphite is oxidized by an acidic permanganate solution (1.0 10(-2) mol L-1 KMnO4 + 1.0 mol L-1 H2SO4) in a heated reactor (50 degreesC). The phosphate generated is then determined by the molybdenum blue method. Influence of flow rates, temperature, and concentration and order of addition of reagents, sample volume, and reactor configuration for the blue complex formation on recorded signals were investigated. The pow system was applied to phosphite determination in commercial samples of liquid fertilizers. The proposed system handles about 80 samples per hour [0.05-0.40% (w/v) H3PO3; R = 0,9998], consuming about 80 muL sample, 1 mg KMnO4, 25 mg (NH)(6)Mo7O24, and Ia mg ascorbic acid per determination. Results are precise [relative standard deviation less than or equal to 3.5% for 0.1% (w/v) H3PO3, n = 12] and in agreement with those obtained by gravimetry at 95% confidence level. (C) 2000 John Wiley & Sons, Inc.en
dc.description.affiliationUniv Estadual Paulista, Inst Quim, Dept Quim Anal, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Inst Quim, Dept Quim Anal, BR-14801970 Araraquara, SP, Brazil
dc.format.extent286-290
dc.identifierhttp://dx.doi.org/10.1002/1098-2728(2000)12:6<286
dc.identifier.citationLaboratory Robotics and Automation. Hoboken: John Wiley & Sons Inc., v. 12, n. 6, p. 286-290, 2000.
dc.identifier.doi10.1002/1098-2728(2000)12:6<286
dc.identifier.issn0895-7533
dc.identifier.lattes9165109840414837
dc.identifier.urihttp://hdl.handle.net/11449/35837
dc.identifier.wosWOS:000165798300002
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofLaboratory Robotics and Automation
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleSpectrophotometric determination of phosphite in fertilizers in a flow injection system with online sample preparationen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
unesp.author.lattes9165109840414837[5]
unesp.author.orcid0000-0003-2046-995X[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: