Logo do repositório
 

Estudo da influência de diferentes sistemas e protocolos de aquisição em tomografia computadorizada de feixe cônico na acurácia de mensurações de níveis ósseos alveolares

dc.contributor.advisorLopes, Sérgio Lucio Pereira de Castro [UNESP]
dc.contributor.authorOliveira, Victória Geisa Brito de [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2025-04-08T21:06:53Z
dc.date.issued2025-02-19
dc.description.abstractObjetivou-se investigar a influência de diferentes protocolos de aquisição em distintos sistemas tomográficos na acurácia de mensurações ósseas alveolares em exames de Tomografia Computadorizada de Feixe Cônico (TCFC) para avaliação periodontal. Foram adquiridas imagens utilizando uma mandíbula humana seca, no qual marcações pontuais, realizadas com material hiperdenso, foram realizadas nas junções amelocementárias (JAC) referentes às faces vestibulomesial e vestibulodistal dos dentes 34 e 43. Foram realizadas aquisições em quatro sistemas tomográficos diferentes: Veraview® X800; OP300 Pro®; I-Cat Next Generation® e Orthophos XG® - utilizando-se os protocolos (FOV + voxel) disponíveis nestes. As imagens, em seu formato DICOM, foram exportadas para o software OnDemand 3D (Cybermed, Tustin, CA, EUA), onde foram geradas secções paracoronais de cada região de estudo com para padronização dos cortes. As mensurações reais entre as JAC e os correspondentes níveis ósseos alveolares na superfície radicular de cada dente foram realizados utilizando um paquímetro digital para obtenção do padrão-ouro. As medidas de cada face, em cada protocolo, foram feitas em triplicata. As comparações em relação aos parâmetros analisados foram realizadas por meio de ANOVA, com nível de significância de 5%, com análise em relação ao padrão-ouro por meio do teste de Dunnet. Os resultados mostraram que, para os fins desta pesquisa, protocolos com voxel maior e FOV menor se aproximaram do padrão-ouro. Em contraponto, determinados protocolos com voxel menor e FOV maior também se aproximaram do padrão-ouro, sugerindo acurácia considerável também. As TCFC são exames complementares importantes na Periodontia, destacando sua função na avaliação de destruição óssea devido à periodontite. Entre os quatro sistemas avaliados, o sistema iCAT apresentou menor acurácia em relação às medidas in situ, enquanto os outros corroboraram que valores de resolução maiores em associação com FOV menores possibilitam precisão nas mensurações.pt
dc.description.abstractThis study aimed to investigate the influence of different acquisition protocols in distinct tomographic systems on the accuracy of alveolar bone measurements in Cone Beam Computed Tomography (CBCT) examinations for periodontal evaluation. Images were acquired using a dry human mandible, in which punctual markings, made with hyperdense material, were placed at the cementoenamel junctions (CEJ) on the buccal-mesial and buccal-distal surfaces of teeth 34 and 43. Acquisitions were performed in four different tomographic systems: Veraview® X800; OP300 Pro®; I-Cat Next Generation® and Orthophos XG® - using the protocols (FOV + voxel) available in these systems. The images, in their DICOM format, were exported to the OnDemand 3D software (Cybermed, Tustin, CA, USA), where paracoronal sections of each study region were generated to standardize the cuts. The actual measurements between the JAC and the corresponding alveolar bone levels on the root surface of each tooth were performed using a digital caliper to obtain the gold standard. The measurements of each face were made in triplicate for each protocol. Comparisons in relation to the analyzed parameters were performed by means of ANOVA, with a significance level of 5%, with analysis in regard to the gold standard by means of the Dunnet test. The results showed that, for the purposes of this research, protocols with a more significant voxel and smaller FOV approached the gold standard. In contrast, specific protocols with a smaller voxel and larger FOV also approached the gold standard, suggesting considerable accuracy as well. CBCTs are important complementary exams in Periodontics, highlighting their role in evaluating bone destruction due to periodontitis. Among the four systems evaluated, the iCAT system showed lower accuracy compared to in situ measurements, while the others corroborated that higher resolution values , in association with a smaller field of view (FOV), enable precision in measurements.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipId88887.829816/2023-00
dc.identifier.capes33004145070P8
dc.identifier.latteshttp://lattes.cnpq.br/1473780003341865
dc.identifier.urihttps://hdl.handle.net/11449/296238
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso restritopt
dc.subjectTomografia computadorizada de feixe cônicopt
dc.subjectDiagnóstico por imagempt
dc.subjectPrecisão da medição dimensionalpt
dc.subjectPeriodontiapt
dc.subjectPerda óssea alveolarpt
dc.subjectSpiral cone-beam computed tomographyen
dc.subjectDiagnostic imagingen
dc.subjectDimensional measurement accuracyen
dc.subjectPeriodonticsen
dc.subjectAlveolar bone lossen
dc.titleEstudo da influência de diferentes sistemas e protocolos de aquisição em tomografia computadorizada de feixe cônico na acurácia de mensurações de níveis ósseos alveolarespt
dc.title.alternativeStudy of the influence of different acquisition systems and protocols in cone beam computed tomography on the accuracy of alveolar bone level measurementsen
dc.typeDissertação de mestradopt
dspace.entity.typePublication
relation.isAuthorOfPublication3178a75d-635b-4d63-b7c7-291078a5f9f3
relation.isAuthorOfPublication.latestForDiscovery3178a75d-635b-4d63-b7c7-291078a5f9f3
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.embargo24 meses após a data da defesapt
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramCiências Aplicadas à Saúde Bucal - ICTpt
unesp.knowledgeAreaPeriodontiapt
unesp.researchAreaImaginologia em Clínica Odontológicapt

Arquivos

Pacote original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
oliveira_vgb_me_sjc_int.pdf
Tamanho:
1.64 MB
Formato:
Adobe Portable Document Format
Carregando...
Imagem de Miniatura
Nome:
oliveira_vgb_me_sjc_par.pdf
Tamanho:
331.04 KB
Formato:
Adobe Portable Document Format

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
2.14 KB
Formato:
Item-specific license agreed upon to submission
Descrição: