Publicação: Electrical Modelling and Power Quality Analysis of Three-Phase Induction Furnace
dc.contributor.author | Moreira, Alexandre C. | |
dc.contributor.author | Silva, Luiz C. P. da | |
dc.contributor.author | Morales Paredes, Helmo K. [UNESP] | |
dc.contributor.author | IEEE | |
dc.contributor.institution | Universidade Estadual de Campinas (UNICAMP) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2019-10-04T12:29:38Z | |
dc.date.available | 2019-10-04T12:29:38Z | |
dc.date.issued | 2014-01-01 | |
dc.description.abstract | The induction furnaces are loads having high power and nonlinear characteristic. The power consumption depends on the stage of melting metal in its interior and can cause serious problems on the electric power distribution systems, such as voltage fluctuations, voltage sags, current harmonics and voltage distortion. Thus, this paper presents the modeling and computational simulation of a six-pulse induction furnace, in order to contribute in power quality studies and connection disturbing loads in electrical power systems. The model of the induction furnace was implemented in PSIM software and used for analysis and evaluation of the potential impacts due to the connection of the induction furnace on the electrical power system, as well as the power quality. Furthermore, an analysis of the power quantities of IEEE 1459 standard are presented. | en |
dc.description.affiliation | Univ Estadual Campinas, Power Syst Dept, UNICAMP, Campinas, SP, Brazil | |
dc.description.affiliation | Univ Estadual Paulista, Control & Automat Engn, Sorocaba, SP, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Control & Automat Engn, Sorocaba, SP, Brazil | |
dc.format.extent | 415-419 | |
dc.identifier.citation | 2014 Ieee 16th International Conference On Harmonics And Quality Of Power (ichqp). New York: Ieee, p. 415-419, 2014. | |
dc.identifier.issn | 2164-0610 | |
dc.identifier.uri | http://hdl.handle.net/11449/184734 | |
dc.identifier.wos | WOS:000343776100086 | |
dc.language.iso | eng | |
dc.publisher | Ieee | |
dc.relation.ispartof | 2014 Ieee 16th International Conference On Harmonics And Quality Of Power (ichqp) | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.subject | Disturbing Load | |
dc.subject | Harmonic Distortion | |
dc.subject | Induction Furnace | |
dc.subject | Power Quality | |
dc.subject | Modeling | |
dc.subject | STD 1459-2010 | |
dc.title | Electrical Modelling and Power Quality Analysis of Three-Phase Induction Furnace | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.ieee.org/publications_standards/publications/rights/rights_policies.html | |
dcterms.rightsHolder | Ieee | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, Sorocaba | pt |
unesp.department | Engenharia de Controle e Automação - ICTS | pt |