Publicação: Evaluation of lines of boron, phosphorus and sulfur by high-resolution continuum source flame atomic absorption spectrometry for plant analysis
dc.contributor.author | Bechlin, Marcos André [UNESP] | |
dc.contributor.author | Gomes Neto, José Anchieta [UNESP] | |
dc.contributor.author | Nóbrega, Joaquim Araújo | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | |
dc.date.accessioned | 2014-05-27T11:29:49Z | |
dc.date.available | 2014-05-27T11:29:49Z | |
dc.date.issued | 2013-07-01 | |
dc.description.abstract | The wavelength-integrated absorbance (WIA) and summation of absorbance (∑ lines) of different lines were evaluated to enhance sensitivity and determine B, P and S in medicinal plants by HR-CS FAAS. The lowest LOD for B (0.5mgL-1) and P (13.7mgL-1) was obtained by integration of lines 249.773nm (3pixels) and 247.620nm (5pixels), respectively. The ∑ lines for CS at 257.595nm and 257.958nm furnished LOD=30.5mgL-1, ca. 10% lower than the LOD obtained for the WIA using 257.595nm and 5pixels. Data showed the advantage of WIA over ∑ lines to improve sensitivity for all analytes. Under optimized conditions, calibration curves in the 1.0-100mgL-1 B and 50.0-2000mgL-1 P, S ranges were consistently obtained. Results obtained with the HR-CS FAAS method were in agreement at 98% and 95% confidence level with certified values for B and P, respectively. And results for S were in accordance to non-certified values. Concentrations of B, P, and S in 12 medicinal plants analyzed by the proposed method varied within the 19.4-34.5mgkg-1 B, 719-3910mgkg-1 P and 1469-7653mgkg-1 S ranges. © 2012 Elsevier B.V. | en |
dc.description.affiliation | UNESP Univ. Estadual Paulista Analytical Chemistry Department, PO Box 355, 14801-970, Araraquara SP | |
dc.description.affiliation | Federal University of São Carlos Department of Chemistry, 13560-970, São Carlos SP | |
dc.description.affiliationUnesp | UNESP Univ. Estadual Paulista Analytical Chemistry Department, PO Box 355, 14801-970, Araraquara SP | |
dc.format.extent | 134-138 | |
dc.identifier | http://dx.doi.org/10.1016/j.microc.2012.03.013 | |
dc.identifier.citation | Microchemical Journal, v. 109, p. 134-138. | |
dc.identifier.doi | 10.1016/j.microc.2012.03.013 | |
dc.identifier.issn | 0026-265X | |
dc.identifier.lattes | 8708735699846578 | |
dc.identifier.scopus | 2-s2.0-84876095881 | |
dc.identifier.uri | http://hdl.handle.net/11449/75770 | |
dc.identifier.wos | WOS:000318665300023 | |
dc.language.iso | eng | |
dc.relation.ispartof | Microchemical Journal | |
dc.relation.ispartofjcr | 2.746 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Boron | |
dc.subject | HR-CS FAAS | |
dc.subject | Medicinal plants | |
dc.subject | Phosphorus | |
dc.subject | Sulfur | |
dc.title | Evaluation of lines of boron, phosphorus and sulfur by high-resolution continuum source flame atomic absorption spectrometry for plant analysis | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8708735699846578 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |