dc.description.abstractThis article shows an analysis of the longitudinal electric parameters of a three-phase transmission line/section using a 280-meter high steel tower. This characteristic, the height of the line conductors and distance between them, are intrinsic related to the longitudinal and transversal parameters of the line. By this means, an accurate study was carried out in order to show the electric variations between a transmission line using the new technology and a three-phase conventional 440 kV line for a wide range of frequencies and a variable soil resistivity. In addition, by using a digital line model, simulations are carried out in time domain to analyze critical overvoltage transients on the studied line. © 2011 IEEE.en
dc.description.affiliationUnicamp - University of Campinas
dc.description.affiliationUnesp - Univ. Estadual Paulista, Ilha Solteira
dc.description.affiliationUnespUnesp - Univ. Estadual Paulista, Ilha Solteira
dc.identifierhttp://dx.doi.org/10.1109/PES.2011.6038984
dc.identifier.citationIEEE Power and Energy Society General Meeting.
dc.identifier.doi10.1109/PES.2011.6038984
dc.identifier.issn1944-9925
dc.identifier.issn1944-9933
dc.identifier.lattes4830845230549223
dc.identifier.scopus2-s2.0-82855163894
dc.identifier.urihttp://hdl.handle.net/11449/73058
dc.language.isoeng
dc.relation.ispartofIEEE Power and Energy Society General Meeting
dc.relation.ispartofsjr0,328
dc.rights.accessRightsAcesso aberto
dc.sourceScopus
dc.subjectelectromagnetic transients
dc.subjectline parameters
dc.subjectsteel towers
dc.subjectTransmission line
dc.subjectDigital line
dc.subjectElectric parameters
dc.subjectElectro-magnetic transient
dc.subjectLine conductors
dc.subjectLine parameters
dc.subjectOvervoltage transient
dc.subjectSoil resistivity
dc.subjectTime domain
dc.subjectTransmission systems
dc.subjectComputer simulation
dc.subjectElectric lines
dc.subjectElectric utilities
dc.subjectTime domain analysis
dc.subjectTransients
dc.subjectTransmission line theory
dc.subjectEngineering exhibitions
dc.titleIntroduction of a non-conventional solution for Amazon transmission system: Analysis of the electric aspectsen
dc.typeTrabalho apresentado em evento
dcterms.licensehttp://www.ieee.org/publications_standards/publications/rights/rights_policies.html
dspace.entity.typePublication
unesp.author.lattes4830845230549223
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentEngenharia Elétrica - FEISpt

Arquivos