Experimental analysis of cold-formed steel channel and lipped-channel profiles connected to roof panel - R-Factor analysis

dc.contributor.authorJavaroni, C. E.
dc.contributor.authorGonçalves, R. M.
dc.contributor.authorMalite, M.
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2022-04-29T08:43:00Z
dc.date.available2022-04-29T08:43:00Z
dc.date.issued2002-12-01
dc.description.abstractThis paper presents and discusses test results of simulated suction effect due wind action on purlin-channel and lipped-channel sections carried out in a vacuum box. The chosen profile sections and their dimensions are those frequently used in steel construction in Brazil. The experimental results and the failure mode analysis of the purlin behaviour subjected to suction effect were compared with the theoretical analysis and R-factor for all load steps. The tests were carried out in a vacuum box with plan dimensions of 4 m × 6 m, where the suction effect due to wind was simulated. The air contained inside the vacuum box was gradually removed by a vacuum cleaner and the results of R-factors were obtained. A total of 15 channel and lipped-channel profiles of 5,740mm length were tested. The first series of tests was carried out without sag rods while the second purlin test was executed with two sag rods, also representing usual situations of those elements in the Brazilian steel construction. The steel panel had a trapezoidal section with 40mm height and 0.65 mm thickness, connected to the profiles using screws. They were measured vertical and horizontal displacements and strains in the middle section of the purlin. Those results allowed an evaluation of the strain and the R-Factor, as proposed by LaBoube (1992, 1991), during each load steps.en
dc.description.affiliationCivil Engineering Department State University of São Paulo, Bauru
dc.description.affiliationDepartment of Structural Engineering University of São Paulo, São Carlos
dc.format.extent523-535
dc.identifier.citationInternational Specialty Conference on Cold-Formed Steel Structures: Recent Research and Developments in Cold-Formed Steel Design and Construction, p. 523-535.
dc.identifier.scopus2-s2.0-3042638650
dc.identifier.urihttp://hdl.handle.net/11449/231000
dc.language.isoeng
dc.relation.ispartofInternational Specialty Conference on Cold-Formed Steel Structures: Recent Research and Developments in Cold-Formed Steel Design and Construction
dc.sourceScopus
dc.titleExperimental analysis of cold-formed steel channel and lipped-channel profiles connected to roof panel - R-Factor analysisen