dc.description.abstract | A simple procedure for the sequential determination of Cd, Cu and Pb in tea leaves by slurry introduction to thermospray flame furnace atomic absorption spectrometry was developed. Detection limits were 0.05 mg kg-1 for Cd, 2.1 mg kg-1 for Cu and 0.68 mg kg-1 for Pb using 0.67 % (m/v) slurries (100 mg/15 mL). © 2013 Springer Science+Business Media New York. | en |
dc.description.affiliation | Departamento de Química Analítica Universidade Estadual Paulista, Caixa Postal 355, Araraquara, CEP 14801-970 | |
dc.description.affiliation | Universidade Federal de Sao Carlos, Centro de Ciencias Exatas e de Tecnologia, Departamento de Quimi, Rodovia Washington Luiz, km 235, Caixa Postal 676, São Carlos, CEP 13565-905 | |
dc.description.affiliationUnesp | Departamento de Química Analítica Universidade Estadual Paulista, Caixa Postal 355, Araraquara, CEP 14801-970 | |
dc.format.extent | 1-4 | |
dc.identifier | http://dx.doi.org/10.1007/s12161-013-9574-z | |
dc.identifier.citation | Food Analytical Methods, p. 1-4. | |
dc.identifier.doi | 10.1007/s12161-013-9574-z | |
dc.identifier.issn | 1936-9751 | |
dc.identifier.issn | 1936-976X | |
dc.identifier.scopus | 2-s2.0-84874379218 | |
dc.identifier.uri | http://hdl.handle.net/11449/74793 | |
dc.identifier.wos | WOS:000326691300014 | |
dc.language.iso | eng | |
dc.relation.ispartof | Food Analytical Methods | |
dc.relation.ispartofjcr | 2.245 | |
dc.relation.ispartofsjr | 0,662 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Scopus | |
dc.subject | Atomic absorption spectrometry | |
dc.subject | Fast sequential | |
dc.subject | Flame furnace | |
dc.subject | Slurry introduction | |
dc.subject | Tea | |
dc.subject | Thermospray | |
dc.title | Sequential Determination of Cd, Cu and Pb in Tea Leaves by Slurry Introduction to Thermospray Flame Furnace Atomic Absorption Spectrometry | en |
dc.type | Artigo | |
dcterms.license | http://www.springer.com/open+access/authors+rights | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |