Study of power quality at the point of common coupling of a low voltage grid and a distributed generation system of 7.8 kWp in a tropical region

dc.contributor.authorGranja, Agustín Valverde
dc.contributor.authorMiguel De Souza, Teófilo [UNESP]
dc.contributor.authorSobrinho, Pedro Magalhães [UNESP]
dc.contributor.authorSantos, Daniel Felipe Arévalo
dc.contributor.institutionUniversidad de Ibagué
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-12-11T16:54:20Z
dc.date.available2018-12-11T16:54:20Z
dc.date.issued2018-06-01
dc.description.abstractIn this paper we analyze an experimental 1000 kWh/month distributed generation system in a tropical region connected to a point of common coupling in a low voltage grid that was characterized according to NTC 5001. This photovoltaic system has 7.8 kWp and uses 30 polycrystalline silicon-panels of 260 Wp each. Its maximum energy produced was 850 kWh/month, equivalent to 72.65% of the installed capacity. Finally, there was an increase of 2% with respect to the minimum voltage value that was recorded. The voltage unbalance decreases between 3.5 and 70% and voltage harmonics in each line increased by 7% on line U1, 0.8% on U2, 3% on U3 and current harmonics have a 22% increase. Likewise, the total active and reactive power were increased by 58% and 42% respectively, and the thermography study allowed to establish a temperature increase at the point of common coupling of 7.5%. Therefore, it is expected that this paper can serve as a reference for the application of Colombian law 1715 in solar energy.en
dc.description.affiliationFacultad de Ingeniería Universidad de Ibagué
dc.description.affiliationSchool of Engineering Universidade Estadual Paulista (UNESP) Câmpus Guaratinguetá
dc.description.affiliationUnespSchool of Engineering Universidade Estadual Paulista (UNESP) Câmpus Guaratinguetá
dc.description.sponsorshipOlympus
dc.description.sponsorshipUniversidad de Jaén
dc.description.sponsorshipUniversidade Estadual Paulista
dc.description.sponsorshipIdOlympus: 15-333-INT
dc.identifierhttp://dx.doi.org/10.3390/en11061539
dc.identifier.citationEnergies, v. 11, n. 6, 2018.
dc.identifier.doi10.3390/en11061539
dc.identifier.file2-s2.0-85049640325.pdf
dc.identifier.issn1996-1073
dc.identifier.lattes6581222571777811
dc.identifier.orcid0000-0001-9606-3265
dc.identifier.scopus2-s2.0-85049640325
dc.identifier.urihttp://hdl.handle.net/11449/171195
dc.language.isoeng
dc.relation.ispartofEnergies
dc.relation.ispartofsjr0,670
dc.rights.accessRightsAcesso abertopt
dc.sourceScopus
dc.subjectExperimental network
dc.subjectLow voltage
dc.subjectPower quality
dc.subjectSolar energy
dc.titleStudy of power quality at the point of common coupling of a low voltage grid and a distributed generation system of 7.8 kWp in a tropical regionen
dc.typeArtigopt
dspace.entity.typePublication
unesp.author.lattes6581222571777811[3]
unesp.author.orcid0000-0001-9606-3265[3]
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia e Ciências, Guaratinguetápt