Logotipo do repositório

Avaliação do comportamento biomecânico e sobrevivência de coroas unitárias em zircônia sobre pilares cad/cam e implantes confeccionados por impressões 3d

dc.contributor.advisorBottino, Marco Antonio [UNESP]
dc.contributor.authorLopes, Guilherme da Rocha Scalzer
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)pt
dc.date.accessioned2026-04-07T12:36:20Z
dc.date.issued2026-03-10
dc.description.abstractThis study aimed to evaluate the fatigue behavior and reliability of two types of CAD/CAM abutments used for single implant-supported reconstructions. Additively manufactured implants with an internal conical connection (4 x 10 mm; Plenum, Jundiaí, SP, Brazil) were used. Half of the implants received Ti-base abutments while the other half received proprietary Plenum abutments (both Ø 4.5 x 1 mm). Zirconia crowns were milled and cemented onto the abutments. Representative specimens were characterized using EDX, XRD, and SEM. Eighteen specimens per group were subjected to step-stress accelerated life testing (15 Hz) through 30 degrees off-axis load application using three loading profiles: mild, moderate, and aggressive until failure or suspension. Failure load and number of cycles were used to calculate use- level probability curves, fatigue beta values, and reliability for 100,000- cycle missions at 50 and 100 N followed by failure-mode analysis. Characterization results confirmed the alloy was composed of titanium, aluminum, vanadium, without β phase. SEM images show a rough but uniform surface. In fatigue testing, β values (>1) suggested failures due to fatigue damage accumulation. Considering the β lower bounds (<1), two- parameter Weibull analysis was conducted (95% CI) revealing no significant differences regarding modulus between groups. However, Ti-base abutments presented higher characteristic strength (140.2 N [134.9-145.7]) compared to Plenum abutments (99.2 N [93.4- 105.2]). For missions at 50 N both groups presented high reliability (≥99%). At 100 N, reliability for Plenum abutments decreased significantly (25%), while the Ti-base group remained above 99%. Failure-mode evaluation revealed that Ti-base specimens failed either at the abutment or abutment-screw, whereas all failures in the Plenum group involved the abutment-screw assembly. Ti- base presented higher characteristic strength and reliability than Plenum abutments. Both abutments on 3D-printed implants presented high reliability for physiologic masticatory forces in the anterior region.en
dc.description.sponsorshipIdNão recebi financiamento
dc.identifier.orcidhttps://orcid.org/0000-0002-4310-0082
dc.identifier.urihttps://hdl.handle.net/11449/320789
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (UNESP)
dc.rights.accessRightsAcesso abertopt
dc.subjectCerâmicapt
dc.subjectImplantes dentáriospt
dc.subjectMateriais dentáriospt
dc.subjectDental Implantsen
dc.subjectDental materialsen
dc.subjectCeramicsen
dc.titleAvaliação do comportamento biomecânico e sobrevivência de coroas unitárias em zircônia sobre pilares cad/cam e implantes confeccionados por impressões 3dpt
dc.title.alternativeEvaluation of the biomechanical behavior and survival of single zirconia crowns on CAD/CAM abutments and implants manufactured by 3D printingen
dc.typeRelatório de pós-docpt
dspace.entity.typePublication
relation.isAuthorOfPublication9e6697e2-a2f1-410f-aa7e-8890be45390f
relation.isAuthorOfPublication.latestForDiscovery9e6697e2-a2f1-410f-aa7e-8890be45390f
relation.isOrgUnitOfPublicationc73b286a-b5fa-4312-a7ec-62f987e7b514
relation.isOrgUnitOfPublication.latestForDiscoveryc73b286a-b5fa-4312-a7ec-62f987e7b514
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.embargoOnlinept

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
lopes_grs_relatorioposdoc_sjc.pdf
Tamanho:
18,74 MB
Formato:
Adobe Portable Document Format