Publicação:
Analysis of implants with laser irradiated surface and silicate deposition

dc.contributor.authorQueiroz, Talita P.
dc.contributor.authorSouza, F. A
dc.contributor.authorLuvizuto, E. R.
dc.contributor.authorMargonar, R.
dc.contributor.authorGuastaldi, Antonio Carlos [UNESP]
dc.contributor.authorGarcia-junior, I. R.
dc.contributor.authorOkamoto, R.
dc.contributor.authorMagro-filho, O.
dc.contributor.authorMarcantonio Júnior, Elcio [UNESP]
dc.contributor.authorVieira, Eduardo Hochuli [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-05-15T13:30:18Z
dc.date.available2015-05-15T13:30:18Z
dc.date.issued2010
dc.description.abstractObjectives: the purpose of this study was to evaluate the surfaces of commercially pure titanium (cpTi) implants surface modified by laser beam (LS), by laser beam associated with sodium silicate deposition (SS) and compare them with surfaces modified by dual-acid etched (AS) and with machined surface (MS). Methods: thirty rabbits received two implants each (one for each tibia). After 30, 60 and 90 days postoperative, the implants were removed by reverse torque for biomechanical analysis and surfaces were analyzed by scanning electron microscopy (SEM) and X-ray energy dispersive spectroscopy (EDS). Results: the mean values of reverse torque at 30, 60 and 90 days postoperative were respectively 24.60, 43.60 e 60.40 N.cm to MS, 43.00, 68.20 e 63.80 N.cm to AS group, 59.80, 76.60 e 78.00 N.cm to LS group and 63.00, 75.40 e 76.60 N.cm to SS group. At 30 days, LS and SS groups showed statistically significant difference (p<0.05) compared to the other groups. At 60 days, LS and SS groups showed statistically significant difference (p<0.05) when compared to MS. Conclusions: it was concluded that SL and SS implants' biomechanical and topographical properties increased bone-implant interaction when compared to the AS and MS implants.en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Físico-Química, Instituto de Química de Araraquara, Araraquara, RUA PROF. FRANCISCO DEGNI, S/N, QUITANDINHA, CEP 14801970, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Físico-Química, Instituto de Química de Araraquara, Araraquara, RUA PROF. FRANCISCO DEGNI, S/N, QUITANDINHA, CEP 14801970, SP, Brasil
dc.identifierhttp://jdr.sagepub.com/
dc.identifier.citationJournal of Dental Research, v. 89, 2010.
dc.identifier.issn0022-0345
dc.identifier.lattes6443430122330366
dc.identifier.lattes6100859465871929
dc.identifier.lattes5535418670745125
dc.identifier.orcid0000-0002-9821-2479
dc.identifier.urihttp://hdl.handle.net/11449/123494
dc.language.isoeng
dc.relation.ispartofJournal of Dental Research
dc.relation.ispartofjcr5.380
dc.relation.ispartofsjr2,302
dc.rights.accessRightsAcesso restrito
dc.sourceCurrículo Lattes
dc.titleAnalysis of implants with laser irradiated surface and silicate depositionen
dc.typeArtigo
dspace.entity.typePublication
unesp.author.lattes6443430122330366[5]
unesp.author.lattes6100859465871929
unesp.author.lattes5535418670745125[8]
unesp.author.lattes6853485483683678[10]
unesp.author.orcid0000-0003-4040-9313[10]
unesp.author.orcid0000-0002-9660-4524[9]
unesp.author.orcid0000-0002-9821-2479[8]
unesp.author.orcid0000-0002-6433-3555[5]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentFísico-Química - IQARpt

Arquivos