Logotipo do repositório
 

Publicação:
Detection of DNA Nucleotides on Pretreated Boron Doped Diamond Electrodes

dc.contributor.authorGarbellini, Gustavo S. [UNESP]
dc.contributor.authorUliana, Carolina V. [UNESP]
dc.contributor.authorYamanaka, Hideko [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T14:19:24Z
dc.date.available2014-05-20T14:19:24Z
dc.date.issued2011-01-01
dc.description.abstractThe individual detection and equimolar mixture of DNA nucleotides guanosine monophosphate (GMP), adenosine monophosphate (AMP), thymidine (TMP) and cytidine (CMP) 5'-monophosphate using square wave voltammetry was performed on boron doped diamond (BDD) electrodes cathodically (Red-DDB) and anodically (Oxi-DDB) pretreated. The oxidation of individual DNA nucleotides was more sensitive on Oxi-BDD electrode. In a simultaneous detection of nucleotides, the responses of GMP, AMP, TMP and CMP were very adequate on both treated electrodes. Particularly, more sensitive and separate peaks for TMP and CMP on Oxi-BDD and Red-BDD electrodes, respectively, were observed after deconvolution procedure. The detection of nucleotides in aqueous solutions will certainly contribute for genotoxic evaluation of substances and hybridization reactions by immobilizing ss or ds-DNA on BDD surface.en
dc.description.affiliationSão Paulo State Univ UNESP, Inst Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationUnespSão Paulo State Univ UNESP, Inst Chem, BR-14800900 Araraquara, SP, Brazil
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 09/08161-8
dc.description.sponsorshipIdFAPESP: 08/08990-1
dc.format.extent1241-1245
dc.identifierhttp://dx.doi.org/10.1590/S0103-50532011000700007
dc.identifier.citationJournal of The Brazilian Chemical Society. São Paulo: Soc Brasileira Quimica, v. 22, n. 7, p. 1241-1245, 2011.
dc.identifier.doi10.1590/S0103-50532011000700007
dc.identifier.fileS0103-50532011000700007.pdf
dc.identifier.issn0103-5053
dc.identifier.lattes1923726000036625
dc.identifier.scieloS0103-50532011000700007
dc.identifier.urihttp://hdl.handle.net/11449/25853
dc.identifier.wosWOS:000293388500007
dc.language.isoeng
dc.publisherSoc Brasileira Quimica
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.relation.ispartofjcr1.444
dc.relation.ispartofsjr0,357
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.subjectDNAen
dc.subjectnucleotidesen
dc.subjectdiamond electrodesen
dc.subjectsurface terminationen
dc.titleDetection of DNA Nucleotides on Pretreated Boron Doped Diamond Electrodesen
dc.typeArtigo
dcterms.rightsHolderSoc Brasileira Quimica
dspace.entity.typePublication
unesp.author.lattes1923726000036625
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição:
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: