Logo do repositório
 

Flow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrode

dc.contributor.authorBergamini, Marcio F.
dc.contributor.authorSantos, Andre L.
dc.contributor.authorStradiotto, Nelson Ramos [UNESP]
dc.contributor.authorZanoni, Maria Valnice Boldrin [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2014-05-20T15:21:50Z
dc.date.available2014-05-20T15:21:50Z
dc.date.issued2007-01-04
dc.description.abstractA rapid and simple method for procaine determination was developed by flow injection analysis (FIA) using a screen-printed carbon electrode (SPCE) as amperometric detector. The present method is based on the amine/hydroxylamine oxidation from procaine monitored at 0.80 V on SPCE in sodium acetate solution pH 6.0. Using the best experimental conditions assigned as: pH 6.0, flow rate of 3.8 mL min(-1), sample volume of 100 mu L and analytical path of 30 cm it is possible to construct a linear calibration curve from 9.0 x 10(-6) to 1.0 x 10(-4) mol L-1. The relative standard deviation for 5.0 x 10(-5) mol L-1 procaine (15 repetitions using the same electrode) is 3.2% and detection limit calculated is 6.0 x 10(-6) mol L-1. Recoveries obtained for procaine gave a mean values from 94.8 to 102.3% and an analytical frequency of 36 injections per hour was achieved. The method was successfully applied for the determination of procaine in pharmaceutical formulation without any pre-treatment, which are in good accordance with the declared values of manufacturer and an official method based on spectrophotometric analysis. (c) 2006 Elsevier B.V. All rights reserved.en
dc.description.affiliationUniv Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, UNESP, Inst Quim, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
dc.format.extent315-319
dc.identifierhttp://dx.doi.org/10.1016/j.jpba.2006.06.001
dc.identifier.citationJournal of Pharmaceutical and Biomedical Analysis. Oxford: Pergamon-Elsevier B.V., v. 43, n. 1, p. 315-319, 2007.
dc.identifier.doi10.1016/j.jpba.2006.06.001
dc.identifier.issn0731-7085
dc.identifier.lattes0072173018005712
dc.identifier.orcid0000-0002-2296-1393
dc.identifier.urihttp://hdl.handle.net/11449/32929
dc.identifier.wosWOS:000243554900041
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofJournal of Pharmaceutical and Biomedical Analysis
dc.relation.ispartofjcr2.831
dc.relation.ispartofsjr0,919
dc.rights.accessRightsAcesso restritopt
dc.sourceWeb of Science
dc.subjectprocainept
dc.subjectFIA amperometricpt
dc.subjectscreen-printed carbon electrodept
dc.titleFlow injection amperometric determination of procaine in pharmaceutical formulation using a screen-printed carbon electrodeen
dc.typeArtigopt
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.author.lattes0072173018005712
unesp.author.orcid0000-0002-2296-1393[4]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: