Publicação: Cathodic stripping voltammetric determination of β-cyfluthrin, a pyrethroid insecticide, using polished silver solid amalgam electrode
dc.contributor.author | Silva, Caio César Gonçalves [UNESP] | |
dc.contributor.author | Silva, Lucas Moreira [UNESP] | |
dc.contributor.author | e Silva, Beatriz Costa [UNESP] | |
dc.contributor.author | Garrido, Saulo Santesso [UNESP] | |
dc.contributor.author | Boldrin, Maria Valnice [UNESP] | |
dc.contributor.author | De Souza, Djenaine | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Toxicological Evaluation & Removal of Micropollutants and Radioactives (INCT-DATREM) | |
dc.contributor.institution | Federal Uberlândia University | |
dc.date.accessioned | 2020-12-12T02:01:28Z | |
dc.date.available | 2020-12-12T02:01:28Z | |
dc.date.issued | 2020-08-01 | |
dc.description.abstract | This work describes an electroanalytical procedure for determination of beta-cyfluthrin (βCF), a pyrethroid insecticide, using polished silver solid amalgam electrode (p-AgSAE) allied to a square-wave cathodic adsorptive stripping voltammetry (SWCASV). Although βCF is non-electroactive in the conventional electrodes, it was accumulated at the p-AgSAE surface as adsorbed mercury salt, allowing their indirect determination using the well-defined reduction peak of mercury complex at − 0.94 V, obtained after adequate experimental and voltammetric optimization. Analytical curves were constructed for βCF, and all analytical parameters were properly evaluated. The proposed methodology was applied in the βCF determination in natural water and tea samples, which were previously filtrated before voltammetric analysis, already the same analysis performed using gas chromatography with mass spectroscopy detection technique employed the solid-phase extraction step. Analytical parameters obtained using both techniques indicated no significant difference at 95% confidence, confirming that the electroanalytical procedure had high robustness, good stability and suitable sensitivity to determination of βCF in complex samples. [Figure not available: see fulltext.]. | en |
dc.description.affiliation | Analytical Chemistry Physical Chemistry and Inorganic Chemistry Department Chemistry Institute Paulista State University (UNESP), Prof. Francisco Degni street, 55 | |
dc.description.affiliation | National Institute for Alternative Technologies of Detection Toxicological Evaluation & Removal of Micropollutants and Radioactives (INCT-DATREM) | |
dc.description.affiliation | Biochemistry and Organic Department Chemistry Institute Paulista State University (UNESP), Prof. Francisco Degni street, 55 | |
dc.description.affiliation | Laboratory of Electroanalytical Applied to Biotechnology and Food Engineering (LEABE) Multidisciplinary Group of Research Science and Technology (RMPCT) Campus of Patos de Minas Federal Uberlândia University, Major Jerônimo street, 566 | |
dc.description.affiliationUnesp | Analytical Chemistry Physical Chemistry and Inorganic Chemistry Department Chemistry Institute Paulista State University (UNESP), Prof. Francisco Degni street, 55 | |
dc.description.affiliationUnesp | Biochemistry and Organic Department Chemistry Institute Paulista State University (UNESP), Prof. Francisco Degni street, 55 | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de Minas Gerais (FAPEMIG) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.format.extent | 1819-1826 | |
dc.identifier | http://dx.doi.org/10.1007/s10008-020-04538-w | |
dc.identifier.citation | Journal of Solid State Electrochemistry, v. 24, n. 8, p. 1819-1826, 2020. | |
dc.identifier.doi | 10.1007/s10008-020-04538-w | |
dc.identifier.issn | 1433-0768 | |
dc.identifier.issn | 1432-8488 | |
dc.identifier.scopus | 2-s2.0-85082922936 | |
dc.identifier.uri | http://hdl.handle.net/11449/200245 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Solid State Electrochemistry | |
dc.source | Scopus | |
dc.subject | Beta-Cyfluthrin | |
dc.subject | Cathodic stripping voltammetry | |
dc.subject | Electroanalytical determination | |
dc.subject | Polished silver solid amalgam electrode | |
dc.subject | Pyrethroids insecticide | |
dc.subject | Tea samples | |
dc.title | Cathodic stripping voltammetric determination of β-cyfluthrin, a pyrethroid insecticide, using polished silver solid amalgam electrode | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0001-7122-1132[4] | |
unesp.author.orcid | 0000-0002-2296-1393[5] | |
unesp.author.orcid | 0000-0001-7180-5912[6] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Bioquímica e Tecnologia - IQAR | pt |
unesp.department | Físico-Química - IQAR | pt |