Publicação: Voltammetric sensor for amoxicillin determination in human urine using polyglutamic acid/glutaraldehyde film
dc.contributor.author | Santos, Daniela P. [UNESP] | |
dc.contributor.author | Bergamini, Marcio F. [UNESP] | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:19:17Z | |
dc.date.available | 2014-05-20T14:19:17Z | |
dc.date.issued | 2008-08-12 | |
dc.description.abstract | A voltammetric sensor for determination of amoxicillin (AMX) was developed based on a glutaraldehyde cross-linked polyglutamic acid modified glassy carbon electrode. The proposed method is based on pre-concentration of AMX by cathodic accumulation as its oxidative product before being determined indirectly at potential as low as +0.23 V by square wave voltammetry. Linear response range, sensitivity and limit of detection were 2.0-25.0, 1.06 and 0.9.2 mu mol L-1, respectively, for AMX in 0.1 mol L-1 acetate buffer pH 5.2, pre-accurnulation time of 60s and accumulation potential of +1.0V. It was demonstrated that the glassy carbon electrode modified with PGA/GLU could be used for AMX determination in human urine without any separation step. (C) 2008 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | Univ São Paulo State, UNESP, Inst Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | Univ São Paulo State, UNESP, Inst Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorshipId | FAPESP: 03/06598-3 | |
dc.description.sponsorshipId | FAPESP: 04/00111-8 | |
dc.format.extent | 398-403 | |
dc.identifier | http://dx.doi.org/10.1016/j.snb.2008.02.045 | |
dc.identifier.citation | Sensors and Actuators B-chemical. Lausanne: Elsevier B.V. Sa, v. 133, n. 2, p. 398-403, 2008. | |
dc.identifier.doi | 10.1016/j.snb.2008.02.045 | |
dc.identifier.issn | 0925-4005 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/25818 | |
dc.identifier.wos | WOS:000259268600008 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. Sa | |
dc.relation.ispartof | Sensors and Actuators B: Chemical | |
dc.relation.ispartofjcr | 5.667 | |
dc.relation.ispartofsjr | 1,406 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | sensor voltammetric | en |
dc.subject | films of polyglutamic acid | en |
dc.subject | amoxicillin | en |
dc.subject | human urine | en |
dc.title | Voltammetric sensor for amoxicillin determination in human urine using polyglutamic acid/glutaraldehyde film | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. Sa | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: