Logotipo do repositório
 

Publicação:
Avaliação biomecânica da atividade dos músculos masseter e temporal usando novo dispositivo intrabucal em pacientes com síndrome de down

dc.contributor.advisorGomes, Mônica Fernandes [UNESP]
dc.contributor.authorTenguan, Vera Lúcia Sizue [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-10-22T17:25:20Z
dc.date.available2018-10-22T17:25:20Z
dc.date.issued2018-08-22
dc.description.abstractEsta pesquisa avaliou por meio de análise eletromiográfica de superfície (EMGs)os efeitos terapêuticos de um dispositivo intrabucalsobre as atividades elétricas dos músculos masseter (porção superficial) e temporal (porção anterior), bilateralmente, em pacientes com síndrome de Down. A amplitude de abertura bucal, a intensidade de força mastigatória total (FMT) foram, também, investigadas por meio de paquímetro e transdutor de força. Adicionalmente, medidas antropométricas, incluindo índice de massa corporal (IMC), circunferências do pescoço (P) e abdominal (A) e relação cintura e quadril (RCQ) foram analisadas antes e após dois meses de terapia com DM. Dez pacientes com síndrome de Down, adultos, de ambos os gêneros, foram submetidos a uma terapia com um dispositivo mastigatório (DM). Os registros eletromiográficos foram realizados para avaliar a atividade elétrica dos músculos masseter e temporal, antes e após a terapia preconizada.Diante dos resultados obtidos, conclui-se que o DM promoveu diminuição das atividades elétricas do músculo temporal em condição de repouso da mandíbula e aumento da abertura bucal, conferindo um possível equilíbrio no sistema muscular mastigatório. A atividade elétrica na contração isométrica do músculo masseter e temporal foi aumentada, sugerindo uma maximização nas unidades motoras. A discreta redução do IMC e da RCQ indica, provavelmente, uma melhoria na distribuição de gordura corporal dos pacientes.Portanto, o DM colaborou para a melhoria do desempenho biomecânico da mastigação.pt
dc.description.abstractThis research evaluated the therapeutic effects of an intrabuccal device on the electrical activities of the masseter (superficial portion) and temporal (anterior portion) muscles, bilaterally, in patients with Down syndrome by means of surface electromyographic analysis (EMGs). The mouth opening amplitude and the total masticatory force intensity (FMT) were also investigated by means of a pachymeter and force transducer. In addition, anthropometric measurements, including body mass index (BMI), neck (P) and abdominal (A) circumference and waist and hip ratio (WHR) were analyzed before and after two months of DM therapy. Ten patients with Down syndrome, adults of both genders, underwent masticatory (DM) therapy. The electromyographic records were performed to evaluate the electrical activity of the masseter and temporal muscles, before and after the recommended therapy. In view of the obtained results, it was concluded that DM promoted a decrease in the electrical activities of the temporal muscle in a condition of rest of the mandible and increase of the buccal opening, conferring a possible balance in the muscular masticatory system. The electrical activity in the isometric contraction of the masseter and temporal muscle was increased, suggesting a maximization in the motor units. The discrete reduction in BMI and WHR probably indicates an improvement in patients' body fat distribution. Therefore, DM collaborated to improve the biomechanical performance of mastication.en
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipIdFAPESP: 2017/06835-8
dc.identifier.aleph000909222
dc.identifier.capes33004145082P6
dc.identifier.lattes1274225455678400
dc.identifier.urihttp://hdl.handle.net/11449/157377
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)
dc.rights.accessRightsAcesso aberto
dc.subjectSíndrome de Downpt
dc.subjectDispositivo mastigatóriopt
dc.subjectHipotonia muscularpt
dc.subjectEletromiografiapt
dc.subjectAntropometriapt
dc.subjectDown syndromeen
dc.subjectMasticatory deviceen
dc.subjectMuscle hypotoniaen
dc.subjectElectromyographyen
dc.subjectAnthropometryen
dc.titleAvaliação biomecânica da atividade dos músculos masseter e temporal usando novo dispositivo intrabucal em pacientes com síndrome de downpt
dc.title.alternativeBiomechanical evaluation of masseter and temporal muscle activity using a new intrabuccal device in patients with Down syndromeen
dc.typeDissertação de mestrado
dspace.entity.typePublication
unesp.advisor.lattes1274225455678400
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Ciência e Tecnologia, São José dos Campospt
unesp.embargo6 meses após a data da defesapt
unesp.graduateProgramCiência e Tecnologia Aplicada à Odontologia - ICTpt
unesp.knowledgeAreaInovação Tecnológicapt
unesp.researchAreaInovação Tecnológica Multidisciplinar com ênfase em Odontologiapt

Arquivos

Pacote Original

Agora exibindo 1 - 2 de 2
Carregando...
Imagem de Miniatura
Nome:
tenguan_vls_me_jjc_int.pdf
Tamanho:
787.6 KB
Formato:
Adobe Portable Document Format
Descrição:
Carregando...
Imagem de Miniatura
Nome:
tenguan_vls_me_jjc_par.pdf
Tamanho:
498.96 KB
Formato:
Adobe Portable Document Format
Descrição:

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
3.03 KB
Formato:
Item-specific license agreed upon to submission
Descrição: