Direct determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometry

dc.contributor.authorGoncalves, Daniel A. [UNESP]
dc.contributor.authorGu, Jiyan
dc.contributor.authorSantos, Mirian C. dos [UNESP]
dc.contributor.authorJones, Bradley T.
dc.contributor.authorDonati, George L.
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionBruker Elemental Inc
dc.contributor.institutionWake Forest Univ
dc.date.accessioned2015-10-21T21:18:24Z
dc.date.available2015-10-21T21:18:24Z
dc.date.issued2015-01-01
dc.description.abstractTungsten coil atomic emission spectrometry (WCAES) is used to determine trace levels of Cr in medicine capsules. No sample preparation other than 10 min vortex mixing with HNO3 and H2O2 is required. Matrix decomposition is carried out directly on the atomizer to minimize matrix effects and improve precision and accuracy. The entire analysis takes less than 12 min per sample including sample preparation. The instrumental setup is based on a tungsten filament extracted from 150 W, 15 V microscope light bulbs, solid state power supply, fused silica lens, crossed Czerny-Turner spectrograph and a thermoelectrically-cooled charge-coupled device detector. The limits of detection (LOD) and quantification (LOQ) for Cr are 3 and 9 mu g L-1, which correspond to procedure LOD and LOQ of 0.4 and 1 mu g g(-1), respectively. These values allow for quantification at a level 28-fold lower than the maximum daily Cr intake from medicine and medicine formulations recommended by the United States Pharmacopeial Convention (USP). The procedure's linear dynamic range is between 3-100 mu g L-1, with a R-2 = 0.9992. It was applied to different empty medicine capsule samples and WCAES results were not significantly different from values found by inductively coupled plasma optical emission spectrometry (ICP OES) by applying a single-factor ANOVA test at the 95% confidence level (p > 0.05). The precision, calculated as %RSD, is between 5.2-7.4%. This is a simple, fast, efficient and potentially portable analytical procedure that may be used in quality control and regulation enforcement applications.en
dc.description.affiliationSao Paulo State Univ, Dept Phys &Chem, BR-15385000 Ilha Solteira, SP, Brazil
dc.description.affiliationBruker Elemental Inc, Kennewick, WA 99336 USA
dc.description.affiliationSao Paulo State Univ, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationWake Forest Univ, Dept Chem, Winston Salem, NC 27109 USA
dc.description.affiliationUnespSao Paulo State Univ, Dept Phys &Chem, BR-15385000 Ilha Solteira, SP, Brazil
dc.description.affiliationUnespSao Paulo State Univ, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil
dc.description.sponsorshipWake Forest University
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipBruker Elemental
dc.description.sponsorshipIdCAPES: 99999.002566/2014-01
dc.format.extent1395-1399
dc.identifierhttp://pubs.rsc.org/en/Content/ArticleLanding/2015/JA/C5JA00100E#!divAbstract
dc.identifier.citationJournal Of Analytical Atomic Spectrometry. Cambridge: Royal Soc Chemistry, v. 30, n. 6, p. 1395-1399, 2015.
dc.identifier.doi10.1039/c5ja00100e
dc.identifier.issn0267-9477
dc.identifier.lattes6566923858579760
dc.identifier.urihttp://hdl.handle.net/11449/129535
dc.identifier.wosWOS:000355559500018
dc.language.isoeng
dc.publisherRoyal Soc Chemistry
dc.relation.ispartofJournal Of Analytical Atomic Spectrometry
dc.relation.ispartofjcr3.608
dc.relation.ispartofsjr1,066
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.titleDirect determination of chromium in empty medicine capsules by tungsten coil atomic emission spectrometryen
dc.typeArtigo
dcterms.rightsHolderRoyal Soc Chemistry
dspace.entity.typePublication
unesp.author.lattes6566923858579760
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.departmentFísica e Química - FEISpt
unesp.departmentQuímica Analítica - IQARpt

Arquivos