Logotipo do repositório
 

Publicação:
Flow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrode

dc.contributor.authorCastro, SSL
dc.contributor.authorBalbo, V. R.
dc.contributor.authorBarbeira, PJS
dc.contributor.authorStradiotto, Nelson Ramos [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Federal de Minas Gerais (UFMG)
dc.date.accessioned2014-05-20T15:25:28Z
dc.date.available2014-05-20T15:25:28Z
dc.date.issued2001-08-30
dc.description.abstractThe PB film-modified electrode was used as an amperometric detector for flow injection analysis of ascorbic acid. The modified electrode detector showed good sensitivity, stability and reproducibility. The calibration curve for ascorbic acid was linear over the concentration range from 5.0 x 10(-6) to 1.0 x 10(-3) mol l(-1) with a slope of 19.9 mA mol(-1) per litre and a correlation coefficient of 0.999. The detection limit of this method was 2.49 x 10(-6) mol l(-1). The relative standard deviation of six replicate injections of 2.5 x 10(-4) mol l(-1) ascorbic acid was 2.5%. The results obtained for ascorbic acid determination in pharmaceutical products are in good agreement with those obtained by using the procedure involving the reaction between triiodide and ascorbic acid. (C) 2001 Elsevier B.V. B.V. All rights reserved.en
dc.description.affiliationUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil
dc.description.affiliationUSP, FFCLRP, Dept Quim, BR-14040901 Ribeirao Preto, SP, Brazil
dc.description.affiliationUniv Fed Minas Gerais, ICEX, Dept Quim Analit, BR-31270901 Belo Horizonte, MG, Brazil
dc.description.affiliationUnespUNESP, Inst Quim, Dept Quim Analit, BR-14800900 Araraquara, SP, Brazil
dc.format.extent249-254
dc.identifierhttp://dx.doi.org/10.1016/S0039-9140(01)00407-6
dc.identifier.citationTalanta. Amsterdam: Elsevier B.V., v. 55, n. 2, p. 249-254, 2001.
dc.identifier.doi10.1016/S0039-9140(01)00407-6
dc.identifier.issn0039-9140
dc.identifier.lattes0072173018005712
dc.identifier.urihttp://hdl.handle.net/11449/35888
dc.identifier.wosWOS:000171174600004
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofTalanta
dc.relation.ispartofjcr4.244
dc.relation.ispartofsjr1,186
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectPrussian Bluept
dc.subjectmodified electrodept
dc.subjectascorbic acidpt
dc.subjectflow systempt
dc.subjectamperometric detectorpt
dc.titleFlow injection amperometric detection of ascorbic acid using a Prussian Blue film-modified electrodeen
dc.typeArtigo
dcterms.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dcterms.rightsHolderElsevier B.V.
dspace.entity.typePublication
unesp.author.lattes0072173018005712
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: