Logotipo do repositório

Espectroscopia ultrassônica para caracterização de misturas de glicerol e água para validação como líquido de referência

dc.contributor.advisorHiguti, Ricardo Tokio [UNESP]
dc.contributor.authorCamargo, Gabrielle Ceola [UNESP]
dc.contributor.committeeMemberHiguti, Ricardo Tokio [UNESP]
dc.contributor.committeeMemberTiago, Marcelo Moreira
dc.contributor.committeeMemberBuiochi, Flávio
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)pt
dc.date.accessioned2026-05-12T13:56:10Z
dc.date.issued2026-01-30
dc.description.abstractNeste trabalho, caracterizam-se misturas binárias de glicerol e água em diferentes concentrações de fração molar, obtendo-se a velocidade de propagação e coeficiente de atenuação acústicos em função da frequência e temperatura, e a densidade, medida com um densímetro. Um espectrômetro acústico composto por um sistema prático de manipulação de amostras utilizando cubetas e controle térmico com estabilidade de 0,01 °C foi utilizado para caracterizar as propriedades acústicas por meio da técnica relativa, na qual as propriedades acústicas do líquido de interesse são medidas a partir de sinais adquiridos com um líquido de referência com propriedades conhecidas, normalmente a água destilada. Para melhorar o alinhamento da cubeta na célula, que inicialmente era feito manualmente, implementou-se um sistema de controle de posicionamento em malha fechada com controlador proporcional (P). Em comparação ao ajuste manual, a automatização evitou a abertura constante do compartimento térmico, garantindo a fixação da cubeta e a estabilidade mecânica necessária durante as medições. Como principal contribuição, estruturou-se uma base de dados parametrizada das propriedades destas misturas. A validação dos resultados, obtidos pelo método relativo, utilizando a água destilada como líquido de referência, evidenciou elevada concordância com a literatura, apresentando erros relativos inferiores a 1% para ensaios com cubetas de caminho acústico de 2 mm e 4 mm. Além disso, a realização de medidas relativas de líquidos atenuantes utilizando a água destilada apresenta limitação de banda útil, uma vez que a alta atenuação da amostra resulta em pouca sobreposição dos espectros e deteriora a relação sinal-ruído. Como proposta de melhoria, e com o conhecimento das propriedades das misturas, estas foram usadas como substituto da água destilada como líquido de referência, com vantagens para a caracterização de fluidos mais atenuantes, como os óleos de rícino e de oliva. Por meio da metodologia proposta, obteve-se maior similaridade espectral e estendeu-se a faixa de frequência com dados válidos de coeficiente de atenuação, evitando a perda de informação em altas frequências e viabilizando a caracterização de fluidos atenuantes.pt
dc.description.abstractIn this work, binary mixtures of glycerol and water at different mole fractions are characterized, obtaining the acoustic propagation velocity and attenuation coefficient as a function of frequency and temperature, as well as density, measured with a densimeter. An acoustic spectrometer composed of a practical sample handling system using cuvettes and thermal control with a stability of 0.01 °C was used to characterize the acoustic properties through the relative technique, in which the acoustic properties of the liquid of interest are measured from signals acquired with a reference liquid with known properties, usually distilled water. To improve the cuvette alignment within the cell, which was initially performed manually, a closed-loop positioning control system with a proportional (P) controller was implemented. Compared to the manual adjustment, the automation avoided the constant opening of the thermal compartment, ensuring cuvette fixation and the necessary mechanical stability during measurements. As a main contribution, a parameterized database of these mixtures' properties was structured. Validation of the results, obtained by the relative method using distilled water as the reference liquid, showed high agreement with the literature, presenting relative errors below 1% for tests with 2 mm and 4 mm acoustic path cuvettes. Furthermore, performing relative measurements of attenuating liquids using distilled water presents a useful bandwidth limitation, since the high attenuation of the sample results in little overlap of the spectra and deteriorates the signal-to-noise ratio. As a proposed improvement, and with the knowledge of the mixture properties, these were used as a substitute for distilled water as the reference liquid, offering advantages for the characterization of more attenuating fluids, such as castor and olive oils. Through the proposed methodology, greater spectral similarity was achieved and the frequency range with valid attenuation coefficient data was extended, avoiding the loss of information at high frequencies and enabling the characterization of attenuating fluids.en
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)pt
dc.description.sponsorshipIdCAPES: 88887.941504/2024-00
dc.identifier.capes33004099080P0
dc.identifier.citationCAMARGO, Gabrielle Ceola. Espectroscopia ultrassônica para caracterização de misturas de glicerol e água para validação como líquido de referência. 2026. Dissertação (Mestrado em Engenharia Elétrica) - Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira, 2026pt
dc.identifier.orcid0000-0001-5172-8956
dc.identifier.urihttps://hdl.handle.net/11449/323713
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)pt
dc.rights.accessRightsAcesso abertopt
dc.subjectUltrassompt
dc.subjectGlicerolpt
dc.subjectEspectroscopia ultrassônicapt
dc.subjectVelocidade do sompt
dc.subjectCoeficiente de atenuaçãopt
dc.subjectUltrasounden
dc.subjectGlycerolen
dc.subjectUltrasonic spectroscopyen
dc.subjectSpeed of sounden
dc.subjectAttenuation coefficienten
dc.titleEspectroscopia ultrassônica para caracterização de misturas de glicerol e água para validação como líquido de referênciapt
dc.title.alternativeUltrasonic spectroscopy for characterization of glycerol and water mixtures for validation as a reference liquiden
dc.typeDissertação de mestradopt
dspace.entity.typePublicationen
relation.isAuthorOfPublication063f398e-b004-4a7e-a021-9e69287a3447
relation.isAuthorOfPublication.latestForDiscovery063f398e-b004-4a7e-a021-9e69287a3447
relation.isGradProgramOfPublication909f8040-719f-42cf-a550-e298b801fceb
relation.isGradProgramOfPublication.latestForDiscovery909f8040-719f-42cf-a550-e298b801fceb
relation.isOrgUnitOfPublication85b724f4-c5d4-4984-9caf-8f0f0d076a19
relation.isOrgUnitOfPublication.latestForDiscovery85b724f4-c5d4-4984-9caf-8f0f0d076a19
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.embargoOnlinept
unesp.examinationboard.typeBanca públicapt
unesp.graduateProgramEngenharia Elétrica - FEISpt
unesp.knowledgeAreaAutomaçãopt
unesp.researchAreaNão constapt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
camargo_gc_me_ilha.pdf
Tamanho:
6,16 MB
Formato:
Adobe Portable Document Format