Publicação: Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acid
dc.contributor.author | Raposo, Jorge L. [UNESP] | |
dc.contributor.author | Oliveira, Silvana R. [UNESP] | |
dc.contributor.author | Nobrega, Joaquim A. | |
dc.contributor.author | Gomes Neto, José Anchieta [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | |
dc.date.accessioned | 2014-05-20T14:19:11Z | |
dc.date.available | 2014-05-20T14:19:11Z | |
dc.date.issued | 2008-09-01 | |
dc.description.abstract | In this work the least-squares background correction (LSBC) and internal standardization (IS) techniques were combined to eliminate spectral and transport interferences in the determination of Pb in phosphoric acid by high-resolution continuum source atomic absorption spectrometry (HR-CS AAS). Blanks, samples and reference solutions [0.10-1.00 mg L-1 Ph in 1% (v/v) HNO3] were spiked with 4.00 mg L-1 Co used as internal standard. For absorbance measurements at the wavelength integrated absorbance equivalent to 9 pixels, correlations between the ratio of absorbance of Ph to absorbance of Co and the analyte concentration were close to 0.9992. Relative standard deviations of measurements varied from 0.6 to 4% and 1 to 7% (n = 12) without and with IS/LSBC techniques, respectively. Recoveries for Ph spikes were in the 96-104% and 76-180% range with and without IS/LSBC, respectively. The limit of detection improved with IS/LSBC techniques. Accuracy of the proposed method was checked for the determinations of Ph in commercial phosphoric acid samples and results obtained with IS were better than those without IS. (C) 2008 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Inst Chem, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliation | Universidade Federal de São Carlos (UFSCar), Dept Quim, BR-13560970 São Carlos, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Inst Chem, Dept Analyt Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.format.extent | 992-995 | |
dc.identifier | http://dx.doi.org/10.1016/j.sab.2008.05.003 | |
dc.identifier.citation | Spectrochimica Acta Part B-atomic Spectroscopy. Oxford: Pergamon-Elsevier B.V. Ltd, v. 63, n. 9, p. 992-995, 2008. | |
dc.identifier.doi | 10.1016/j.sab.2008.05.003 | |
dc.identifier.issn | 0584-8547 | |
dc.identifier.lattes | 8708735699846578 | |
dc.identifier.uri | http://hdl.handle.net/11449/25783 | |
dc.identifier.wos | WOS:000259931500012 | |
dc.language.iso | eng | |
dc.publisher | Pergamon-Elsevier B.V. Ltd | |
dc.relation.ispartof | Spectrochimica Acta Part B-atomic Spectroscopy | |
dc.relation.ispartofjcr | 2.854 | |
dc.relation.ispartofsjr | 0,960 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | Lead | en |
dc.subject | Phosphoric acid | en |
dc.subject | Least Least-squares background correction | en |
dc.subject | Internal standardization | en |
dc.subject | High-resolution continuum source atomic | en |
dc.subject | absorption spectrometry | en |
dc.title | Internal standardization and least-squares background correction in high-resolution continuum source flame atomic absorption spectrometry to eliminate interferences on determination of Pb in phosphoric acid | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Pergamon-Elsevier B.V. Ltd | |
dspace.entity.type | Publication | |
unesp.author.lattes | 8708735699846578 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: