Publicação: Age-related differences in time-limit performance and force platform-based balance measures during one-leg stance
dc.contributor.author | Da Silva, Rubens A. | |
dc.contributor.author | Bilodeau, Martin | |
dc.contributor.author | Parreira, Rodolfo B. | |
dc.contributor.author | Teixeira, Denilson C. | |
dc.contributor.author | Amorim, César F. [UNESP] | |
dc.contributor.institution | Universidade Norte do Paraná (UNOPAR) | |
dc.contributor.institution | Universidade Estadual de Londrina (UEL) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Élisabeth Bruyère Research Institute | |
dc.date.accessioned | 2014-05-27T11:29:35Z | |
dc.date.available | 2014-05-27T11:29:35Z | |
dc.date.issued | 2013-06-01 | |
dc.description.abstract | Poor posture control has been associated with an increased risk of falls and mobility disability among older adults. This study was conducted to assess the test-retest reliability and sensitivity to group differences regarding the time-limit (TLimit) of one-leg standing and selected balance parameters obtained with a force platform in older and young adults. A secondary purpose was to assess the relationship between TLimit and these balance parameters. Twenty-eight healthy older adults (age: 69±5years) and thirty young adults (age: 21±4years) participated in this study. Two one-leg stance tasks were performed: (1) three trials of 30s maximum and (2) one TLimit trial. The following balance parameters were computed: center of pressure area, RMS sway amplitude, and mean velocity and mean frequency in both the anterio-posterior and medio-lateral directions. All balance parameters obtained with the force platform as well as the TLimit variable were sensitive to differences in balance performance between older and young adults. The test-retest reliability of these measures was found to be acceptable (ICC: 0.40-0.85), with better ICC scores observed for mean velocity and mean frequency in the older group. Pearson correlations coefficients (r) between balance parameters and TLimit ranged from -0.16 to -0.54. These results add to the current literature that can be used in the development of measurement tools for evaluating balance in older and young adults. © 2013 Elsevier Ltd. | en |
dc.description.affiliation | Center for Health Science Research Laboratory of Functional Evaluation and Human Motor Performance Universidade Norte do Paraná (UNOPAR), 675 Paris Ave., CEP 86041-120, Londrina-PR | |
dc.description.affiliation | Masters Program in Rehabilitation Sciences UEL/UNOPAR, 675 Paris Ave., CEP 86041-120, Londrina-PR | |
dc.description.affiliation | Faculty of Engineering Universidade Estadual Paulista - UNESP-FEG/UNICID, Av. Doutor Ariberto Pereira da Cunha, 333, Guaratinguetá, SP 12516-410 | |
dc.description.affiliation | School of Rehabilitation Sciences University of Ottawa Élisabeth Bruyère Research Institute, 43 Bruyere St., Ottawa, ON K1N 5C8 | |
dc.description.affiliation | Physical Education and Sport Center Universidade Estadual de Londrina (UEL) Campus Universitário Londrina, Rod. Celso Garcia Cid. 445 Km 380, PR, 86055-900 | |
dc.description.affiliationUnesp | Faculty of Engineering Universidade Estadual Paulista - UNESP-FEG/UNICID, Av. Doutor Ariberto Pereira da Cunha, 333, Guaratinguetá, SP 12516-410 | |
dc.format.extent | 634-639 | |
dc.identifier | http://dx.doi.org/10.1016/j.jelekin.2013.01.008 | |
dc.identifier.citation | Journal of Electromyography and Kinesiology, v. 23, n. 3, p. 634-639, 2013. | |
dc.identifier.doi | 10.1016/j.jelekin.2013.01.008 | |
dc.identifier.issn | 1050-6411 | |
dc.identifier.issn | 1873-5711 | |
dc.identifier.scopus | 2-s2.0-84876962802 | |
dc.identifier.uri | http://hdl.handle.net/11449/75515 | |
dc.identifier.wos | WOS:000318905600016 | |
dc.language.iso | eng | |
dc.relation.ispartof | Journal of Electromyography and Kinesiology | |
dc.relation.ispartofjcr | 1.568 | |
dc.relation.ispartofsjr | 0,778 | |
dc.rights.accessRights | Acesso restrito | pt |
dc.source | Scopus | |
dc.subject | Aging | |
dc.subject | Biomechanics | |
dc.subject | Force platform | |
dc.subject | Posture | |
dc.subject | Rehabilitation | |
dc.subject | adult | |
dc.subject | age | |
dc.subject | aged | |
dc.subject | anterior posterior axis | |
dc.subject | body equilibrium | |
dc.subject | controlled study | |
dc.subject | correlation coefficient | |
dc.subject | female | |
dc.subject | ground reaction force | |
dc.subject | human | |
dc.subject | human experiment | |
dc.subject | leg | |
dc.subject | male | |
dc.subject | motor performance | |
dc.subject | normal human | |
dc.subject | pressure measurement | |
dc.subject | priority journal | |
dc.subject | sensitivity analysis | |
dc.subject | standing | |
dc.subject | task performance | |
dc.subject | test retest reliability | |
dc.subject | time | |
dc.title | Age-related differences in time-limit performance and force platform-based balance measures during one-leg stance | en |
dc.type | Artigo | pt |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0003-2597-1172[3] | |
unesp.author.orcid | 0000-0001-6879-436X[1] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia e Ciências, Guaratinguetá | pt |