dc.description.abstractDirect solid sampling is proposed for Pb determination in eye shadow and blush samples by high-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS). A mixture of Pd(NO3)2 + Mg(NO3)2 was employed as chemical modifier, and aqueous calibration (0.25-2.5 ng Pb, r = 0.998) was obtained. Accuracy of the determination of Pb in eye shadow and blush samples by the proposed method was verified by line source graphite furnace AAS as a comparative technique employing digested samples. The results obtained by the two methods were in agreement at a 95% confidence level (paired t-test). The limit of quantification (dry mass) was 0.020 ng mg–1. The Pb content in the eye shadow and blush samples varied between 1.222 and 9.632 ng mg–1 and 0.362 and 28.091 ng mg–1, respectively.en
dc.description.abstractA espectrometria de absorção atômica em forno de grafite de alta resolução com fonte contínua (HR-CS GF AAS) é proposta para determinar Pb em sombra de olho e blush empregando a análise direta de sólidos. O emprego da mistura de modificadores químicos Pd(NO3)2 + Mg(NO3)2 possibilitou a calibração aquosa de 0,25 a 2,5 ng Pb (r = 0,998). O desempenho do método proposto foi avaliado por meio da análise de digeridos de sombra e de blush por espectrometria de absorção atômica em forno de grafite com fonte de linhas (LS GF AAS) como técnica comparativa. Os resultados obtidos por HR-CS GF AAS e LS GF AAS foram concordantes entre si a um nível de confiança de 95% (teste t pareado). O limite de quantificação (massa seca) foi de 0,020 ng mg–1. A concentração de Pb nas amostras de sombra de olho e de blush variou de 1,222 a 9,632 ng mg–1 e 0,362 a 28,091 ng mg–1, respectivamente.pt
dc.description.affiliationSão Paulo State University Analytical Chemistry Department
dc.description.affiliationUnespSão Paulo State University Analytical Chemistry Department
dc.description.sponsorshipFundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
dc.description.sponsorshipCoordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
dc.description.sponsorshipConselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
dc.description.sponsorshipIdFAPESP: 09/52480-0
dc.format.extent140-146
dc.identifierhttp://dx.doi.org/10.5935/0103-5053.20140228
dc.identifier.citationJournal of the Brazilian Chemical Society. Sociedade Brasileira de Química, v. 26, n. 1, p. 140-146, 2015.
dc.identifier.doi10.5935/0103-5053.20140228
dc.identifier.fileS0103-50532015000100140.pdf
dc.identifier.issn0103-5053
dc.identifier.lattes9756414550075565
dc.identifier.lattes8708735699846578
dc.identifier.scieloS0103-50532015000100140
dc.identifier.urihttp://hdl.handle.net/11449/122930
dc.language.isoeng
dc.publisherSociedade Brasileira de Química
dc.relation.ispartofJournal of the Brazilian Chemical Society
dc.relation.ispartofjcr1.444
dc.relation.ispartofsjr0,357
dc.rights.accessRightsAcesso abertopt
dc.sourceSciELO
dc.subjectleaden
dc.subjectcosmeticsen
dc.subjectdirect solid samplingen
dc.titleDetermination of lead in eye shadow and blush by high-resolution continuum source graphite furnace atomic absorption spectrometry employing directSolid samplingen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublicationbc74a1ce-4c4c-4dad-8378-83962d76c4fd
relation.isOrgUnitOfPublication.latestForDiscoverybc74a1ce-4c4c-4dad-8378-83962d76c4fd
unesp.author.lattes9756414550075565
unesp.author.lattes8708735699846578
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
S0103-50532015000100140.pdf
Tamanho:
214.73 KB
Formato:
Adobe Portable Document Format
Descrição: