Logotipo do repositório

Impact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect

dc.contributor.authorAsorza, Jesus E. Guevara
dc.contributor.authorColqui, Jaimis S. L.
dc.contributor.authorAraujo, Ricardo A. de
dc.contributor.authorPissolato Filho, Jose
dc.contributor.authorKurokawa, Sergio [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)pt
dc.date.accessioned2026-09-10T00:40:21Z
dc.date.issued2025-08-15
dc.description.abstractThis study presents a detailed analysis of the electrical and thermal interactions of underground power transmission lines, considering ampacity, induced voltages, and induced currents in the sheaths. Mathematical models estimate induced currents in different duct bank configurations (triangular, inverted triangular, flat, and vertical), accounting for geometric variations caused by underground obstructions such as pipelines and gas ducts. Two scenarios are investigated: a realistic case that incorporates the effects of obstructions on cable spacing and depth, and an idealized case that assumes uniform geometry. The study also examines the impact of sectionalized and continuous cross-bonding methods on system performance. The results, applied to a 220 kV double-circuit underground transmission line, demonstrate how real-world conditions directly influence the electrical and thermal characteristics of the system. Finally, engineering recommendations are provided, taking into account the induced currents associated with core temperature rise.
dc.description.affiliationFederal University of Lavras, Sao Sebasti˜ao do Para˜´ıso, Brazil
dc.description.affiliationDepartament of ´ Electrical Engineering, Sao Paulo State University, Ilha Solteira, Brazil
dc.description.affiliationUnespDepartament of ´ Electrical Engineering, Sao Paulo State University, Ilha Solteira, Brazil
dc.identifierhttps://app.dimensions.ai/details/publication/pub.1191792297
dc.identifier.dimensionspub.1191792297
dc.identifier.doi10.1109/tia.2025.3599464
dc.identifier.issn0093-9994
dc.identifier.issn1939-9367
dc.identifier.orcid0009-0008-5422-8533
dc.identifier.orcid0000-0001-5095-7298
dc.identifier.orcid0000-0002-6928-8343
dc.identifier.orcid0000-0002-7932-3974
dc.identifier.orcid0000-0002-9263-980X
dc.identifier.urihttps://hdl.handle.net/11449/331588
dc.publisherInstitute of Electrical and Electronics Engineers (IEEE)
dc.relation.ispartofIEEE Transactions on Industry Applications; n. 99; v. PP; p. 1-12
dc.rights.accessRightsAcesso restritopt
dc.rights.sourceRightsclosed
dc.sourceDimensions
dc.titleImpact of Underground Obstructions in Double-Circuit Underground Power Lines: Ampacity and Induced Effect
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication85b724f4-c5d4-4984-9caf-8f0f0d076a19
relation.isOrgUnitOfPublication.latestForDiscovery85b724f4-c5d4-4984-9caf-8f0f0d076a19
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt

Arquivos