Measurement of Wave Attenuation in Buried Plastic Water Distribution Pipes
Loading...
External sources
External sources
Date
Advisor
Coadvisor
Graduate program
Undergraduate course
Journal Title
Journal ISSN
Volume Title
Publisher
Assoc Mechanical Engineers Technicians Slovenia
Faculty of Mechanical Engineering
Faculty of Mechanical Engineering
Type
Article
Access right
Acesso aberto

External sources
External sources
Abstract
Leaks in pipes are a common issue encountered in the water industry. Acoustic methods are generally successful in finding and locating leaks in metallic pipes, however, they are less effective when applied to plastic pipes. This is because leak-noise signals are heavily attenuated due to high damping in the pipe-wall and sound radiation into the soil. As result, high frequency leak noise does not travel long distances. To determine how far leak noise may travel in a pipe at any frequency, the attenuation of the wave responsible for leak noise propagation should be known. In this paper a new method to estimate this is described. The method is then applied to some measurements made on a bespoke pipe-test rig in the UK, and the results are compared with theoretical predictions.
Description
Keywords
Language
English
Citation
Strojniski Vestnik-journal Of Mechanical Engineering. Ljubljana: Assoc Mechanical Engineers Technicians Slovenia, v. 60, n. 5, p. 298-306, 2014.