Publicação: Use of a carbon paste electrode modified with spinel-type manganese oxide as a potentiometric sensor for lithium ions in flow injection analysis
dc.contributor.author | Teixeira, MFS | |
dc.contributor.author | Cavalheiro, ETG | |
dc.contributor.author | Bergamini, M. F. | |
dc.contributor.author | Moraes, F. C. | |
dc.contributor.author | Bocchi, N. | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T15:20:47Z | |
dc.date.available | 2014-05-20T15:20:47Z | |
dc.date.issued | 2004-04-01 | |
dc.description.abstract | A potentiometric sensor constructed from a mixture of 25% (m/m) spinel-type manganese oxide (lambda-MnO2), 50% (m/m) graphite powder and 25% (m/m) mineral oil is used for the determination of lithium ions in a flow injection analysis system. Experimental parameters, such as pH of the carrier solution, flow rate, injection sample volume, and selectivity for Li+ against other alkali and alkaline-earth ions and the response time of this sensor were investigated. The sensor response to lithium ions was linear in the concentration range 8.6 x 10(-5) - 1.0 x 10(-2) mol L-1 with a slope 78.9 +/- 0.3 mV dec(-1) over a wide pH range 7 - 10 (Tris buffer), without interference of other alkali and alkaline-earth metals. For a flow rate of 5.0 mL min(-1) and a injection sample volume of 408.6 muL, the relative standard deviation for repeated injections of a 5.0 x 10(-4) mol L-1 lithium ions was 0.3%. | en |
dc.description.affiliation | USP, IQSC, Dept Quim & Fis Mol, BR-13560970 Sao Carlos, SP, Brazil | |
dc.description.affiliation | Univ Fed Sao Carlos, Ctr Ciências Exatas & Tecnol, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil | |
dc.description.affiliationUnesp | UNESP – Campus do Litoral Paulista, CEP 11330-900 – São Vicente, SP, Brazil | |
dc.format.extent | 633-639 | |
dc.identifier | http://dx.doi.org/10.1002/elan.200302850 | |
dc.identifier.citation | Electroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 16, n. 8, p. 633-639, 2004. | |
dc.identifier.doi | 10.1002/elan.200302850 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.uri | http://hdl.handle.net/11449/32010 | |
dc.identifier.wos | WOS:000221285600004 | |
dc.language.iso | eng | |
dc.publisher | Wiley-Blackwell | |
dc.relation.ispartof | Electroanalysis | |
dc.relation.ispartofjcr | 2.851 | |
dc.relation.ispartofsjr | 0,692 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | potentiometric sensor | pt |
dc.subject | lambda-manganese oxide | pt |
dc.subject | lithium ions | pt |
dc.subject | flow injection analysis | pt |
dc.title | Use of a carbon paste electrode modified with spinel-type manganese oxide as a potentiometric sensor for lithium ions in flow injection analysis | en |
dc.type | Artigo | |
dcterms.license | http://olabout.wiley.com/WileyCDA/Section/id-406071.html | |
dcterms.rightsHolder | Wiley-Blackwell | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, São Vicente | pt |
unesp.department | Ciências Biológicas - IBCLP | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: