Publicação: Measurement of orthovoltage X-ray intensity with a lithium niobate transducer
dc.contributor.author | Pontes, Wesley [UNESP] | |
dc.contributor.author | De Carvalho, Aparecido Augusto [UNESP] | |
dc.contributor.author | Sanches, Marcelo Augusto Assunção [UNESP] | |
dc.contributor.author | De Freitas, Ricardo Luiz Barros [UNESP] | |
dc.contributor.author | De Paula, Mauro Henrique | |
dc.contributor.author | Sakamoto, Walter Katsumi [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Federal University of Mato Grosso Do Sul | |
dc.date.accessioned | 2014-05-27T11:24:03Z | |
dc.date.available | 2014-05-27T11:24:03Z | |
dc.date.issued | 2009-12-01 | |
dc.description.abstract | A microcontrolled instrument for measuring the energy fluence rate (or intensity) of X-ray pulses in the orthovoltage range of 120 to 300 kV is described. The prototype instrument consists of a pyroelectric sensor, a low-noise highsensitivity current-to-voltage converter, a microcontroller and a digital display. The response of the instrument is nonlinear with the intensity of the radiation. The precision is better than 3%. The equipment is inexpensive, rugged, simple to construct and has good long-term stability. © 2009 Springer-Verlag. | en |
dc.description.affiliation | Department of Electrical Engineering São Paulo State University - UNESP, Avenida Brasil, 56, Ilha Solteira | |
dc.description.affiliation | Physics Department Federal University of Mato Grosso Do Sul, Campo Grande, MS 79070-900 | |
dc.description.affiliation | Depto. Physics and Chemistry São Paulo State University - UNESP, Ilha Solteira, SP 15385-000 | |
dc.description.affiliationUnesp | Department of Electrical Engineering São Paulo State University - UNESP, Avenida Brasil, 56, Ilha Solteira | |
dc.description.affiliationUnesp | Depto. Physics and Chemistry São Paulo State University - UNESP, Ilha Solteira, SP 15385-000 | |
dc.format.extent | 667-670 | |
dc.identifier | http://dx.doi.org/10.1007/978-3-642-03902-7-192 | |
dc.identifier.citation | IFMBE Proceedings, v. 25, n. 3, p. 667-670, 2009. | |
dc.identifier.doi | 10.1007/978-3-642-03902-7-192 | |
dc.identifier.issn | 1680-0737 | |
dc.identifier.lattes | 0250066159980825 | |
dc.identifier.lattes | 0896348165708140 | |
dc.identifier.lattes | 8630973561889272 | |
dc.identifier.scopus | 2-s2.0-77950124310 | |
dc.identifier.uri | http://hdl.handle.net/11449/71267 | |
dc.language.iso | eng | |
dc.relation.ispartof | IFMBE Proceedings | |
dc.relation.ispartofsjr | 0,143 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Scopus | |
dc.subject | Energy fluence rate | |
dc.subject | Microcontrolled instrument | |
dc.subject | Orthovoltage range | |
dc.subject | Pyroelectric sensor | |
dc.subject | X-ray intensity | |
dc.subject | Energy fluences | |
dc.subject | Orthovoltage | |
dc.subject | Pyroelectric sensors | |
dc.subject | X ray intensity | |
dc.subject | Biomedical engineering | |
dc.subject | Dosimetry | |
dc.subject | Instruments | |
dc.subject | Lithium | |
dc.subject | Niobium compounds | |
dc.subject | Physics | |
dc.subject | Radiation shielding | |
dc.subject | Sensors | |
dc.subject | X rays | |
dc.subject | Biological radiation effects | |
dc.title | Measurement of orthovoltage X-ray intensity with a lithium niobate transducer | en |
dc.type | Trabalho apresentado em evento | |
dcterms.license | http://www.springer.com/open+access/authors+rights | |
dspace.entity.type | Publication | |
unesp.author.lattes | 0250066159980825[2] | |
unesp.author.lattes | 0896348165708140 | |
unesp.author.lattes | 8630973561889272 | |
unesp.author.orcid | 0000-0001-8204-3482[2] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira | pt |
unesp.department | Engenharia Elétrica - FEIS | pt |
unesp.department | Física e Química - FEIS | pt |