Logotipo do repositório

A Solid Film Electrode of Intermetallic Ag 2 Hg 3.02 for the Direct Determination of Folic Acid in Fresh and Processed Fruit Juices

dc.contributor.authorPaula, Cleide Garcia de
dc.contributor.authorToledo, Renata Alves de
dc.contributor.authorVaz, Carlos Manoel Pedro
dc.contributor.authorCordeiro, Paulo Jorge Marques
dc.contributor.authorBatistuti, José Paschoal
dc.contributor.authorPastre, Ieda Aparecida
dc.contributor.authorShim, Hojae
dc.contributor.authorFertonani, Fernando Luís Fertonani [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2015-04-27T11:56:05Z
dc.date.available2015-04-27T11:56:05Z
dc.date.issued2014
dc.description.abstractAgSIE was used for the direct analysis of folic acid (FA), with a detection limit and lower level of quantitation of 6.8 x10-10 mol L-1 and 2.3 x 10 8 mol L-1. The analysis in fresh and processed fruits was done without any sample pretreatment. In strawberry and acerola juices, FA concentration level values were below the method detection limit. FA was detectable in peach (77.7 0.4 mg L-1 and 64.4 0.5 mgL-1), Persian lime (45.4 0.7 mg L-1), pineapple Hawaii (66.2 0.4 mgL-1), pear pineapple (35.3 0.6 mgL-1), cashew (54.4 0.5 mgL-1) , passion fruit (73.2 0.3 mgL-1), and apple (84.4 0.5 mg L-1 ).en
dc.description.affiliationUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química e Ciências Ambientais, Instituto de Biociências Letras e Ciências Exatas de São José do Rio Preto, Sao Jose do Rio Preto, Rua Cristovão Colombo 2265, JARDIN nAZARETH, CEP 14800-900, SP, Brasil
dc.description.affiliationUnespUniversidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química e Ciências Ambientais, Instituto de Biociências Letras e Ciências Exatas de São José do Rio Preto, Sao Jose do Rio Preto, Rua Cristovão Colombo 2265, JARDIN nAZARETH, CEP 14800-900, SP, Brasil
dc.format.extent450-456
dc.identifierhttp://dx.doi.org/10.1002/elan.201400512
dc.identifier.citationElectroanalysis, v. 27, n. 2, p. 450-456, 2015.
dc.identifier.dimensionspub.1037038975
dc.identifier.doi10.1002/elan.201400512
dc.identifier.issn1040-0397
dc.identifier.issn1521-4109
dc.identifier.lattes2453255846842174
dc.identifier.orcid0000-0003-2893-8028
dc.identifier.orcid0000-0003-3855-2233
dc.identifier.orcid0000-0002-8121-7329
dc.identifier.orcid0000-0003-2137-9964
dc.identifier.urihttp://hdl.handle.net/11449/122841
dc.language.isoeng
dc.publisherWiley
dc.relation.ispartofElectroanalysis
dc.relation.ispartofjcr2.851
dc.relation.ispartofsjr0,692
dc.rights.accessRightsAcesso restritopt
dc.sourceCurrículo Lattes
dc.sourceDimensions
dc.subjectDetermination the folic aciden
dc.subjectFruit Juicesen
dc.subjectSWAdSVen
dc.subjectIntermetallic Ag 2 Hg 3.02en
dc.subjectSEM imagesen
dc.subjectXRDen
dc.titleA Solid Film Electrode of Intermetallic Ag 2 Hg 3.02 for the Direct Determination of Folic Acid in Fresh and Processed Fruit Juicesen
dc.typeArtigopt
dspace.entity.typePublication
relation.isOrgUnitOfPublication43c38943-bd6f-4fb6-a9a5-8482a1f632c0
relation.isOrgUnitOfPublication.latestForDiscovery43c38943-bd6f-4fb6-a9a5-8482a1f632c0
unesp.author.lattes2453255846842174
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Biociências, Letras e Ciências Exatas, São José do Rio Pretopt
unesp.departmentQuímica e Ciências Ambientais - IBILCEpt

Arquivos