Publicação: A Solid Film Electrode of Intermetallic Ag 2 Hg 3.02 for the Direct Determination of Folic Acid in Fresh and Processed Fruit Juices
dc.contributor.author | Paula, Cleide Garcia de | |
dc.contributor.author | Toledo, Renata Alves de | |
dc.contributor.author | Vaz, Carlos Manoel Pedro | |
dc.contributor.author | Cordeiro, Paulo Jorge Marques | |
dc.contributor.author | Batistuti, José Paschoal | |
dc.contributor.author | Pastre, Ieda Aparecida | |
dc.contributor.author | Shim, Hojae | |
dc.contributor.author | Fertonani, Fernando Luís Fertonani [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2015-04-27T11:56:05Z | |
dc.date.available | 2015-04-27T11:56:05Z | |
dc.date.issued | 2014 | |
dc.description.abstract | AgSIE was used for the direct analysis of folic acid (FA), with a detection limit and lower level of quantitation of 6.8 x10-10 mol L-1 and 2.3 x 10 8 mol L-1. The analysis in fresh and processed fruits was done without any sample pretreatment. In strawberry and acerola juices, FA concentration level values were below the method detection limit. FA was detectable in peach (77.7 0.4 mg L-1 and 64.4 0.5 mgL-1), Persian lime (45.4 0.7 mg L-1), pineapple Hawaii (66.2 0.4 mgL-1), pear pineapple (35.3 0.6 mgL-1), cashew (54.4 0.5 mgL-1) , passion fruit (73.2 0.3 mgL-1), and apple (84.4 0.5 mg L-1 ). | en |
dc.description.affiliation | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química e Ciências Ambientais, Instituto de Biociências Letras e Ciências Exatas de São José do Rio Preto, Sao Jose do Rio Preto, Rua Cristovão Colombo 2265, JARDIN nAZARETH, CEP 14800-900, SP, Brasil | |
dc.description.affiliationUnesp | Universidade Estadual Paulista Júlio de Mesquita Filho, Departamento de Química e Ciências Ambientais, Instituto de Biociências Letras e Ciências Exatas de São José do Rio Preto, Sao Jose do Rio Preto, Rua Cristovão Colombo 2265, JARDIN nAZARETH, CEP 14800-900, SP, Brasil | |
dc.format.extent | 450-456 | |
dc.identifier | http://dx.doi.org/10.1002/elan.201400512 | |
dc.identifier.citation | Electroanalysis, v. 27, n. 2, p. 450-456, 2015. | |
dc.identifier.doi | 10.1002/elan.201400512 | |
dc.identifier.issn | 1040-0397 | |
dc.identifier.lattes | 2453255846842174 | |
dc.identifier.uri | http://hdl.handle.net/11449/122841 | |
dc.language.iso | eng | |
dc.relation.ispartof | Electroanalysis | |
dc.relation.ispartofjcr | 2.851 | |
dc.relation.ispartofsjr | 0,692 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Currículo Lattes | |
dc.subject | Determination the folic acid | en |
dc.subject | Fruit Juices | en |
dc.subject | SWAdSV | en |
dc.subject | Intermetallic Ag 2 Hg 3.02 | en |
dc.subject | SEM images | en |
dc.subject | XRD | en |
dc.title | A Solid Film Electrode of Intermetallic Ag 2 Hg 3.02 for the Direct Determination of Folic Acid in Fresh and Processed Fruit Juices | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.author.lattes | 2453255846842174 | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Biociências, Letras e Ciências Exatas, São José do Rio Preto | pt |
unesp.department | Química e Ciências Ambientais - IBILCE | pt |