dc.description.abstractEm galpões industriais, os pórticos metálicos, aliados a elementos secundários, como terças e sistemas de contraventamento, possibilitam o vencimento de grandes vãos, conciliando elevada capacidade resistente e rapidez construtiva. Nesse contexto, a escolha do sistema estrutural influencia diretamente no consumo de material, no desempenho estrutural e nos custos da edificação. Dessa forma, o presente trabalho teve como objetivo avaliar comparativamente a taxa de consumo de aço de galpões industriais compostos por pórticos em vigas de alma cheia e pórticos em vigas treliçadas de banzos paralelos, buscando identificar as soluções mais eficientes para diferentes configurações geométricas. Foram analisados modelos estruturais com vãos variando entre 12 m e 24 m, associados a espaçamentos longitudinais entre pórticos de 5 m, 6 m, 7 m e 8 m, totalizando 56 modelos. As modelagens e análises estruturais foram realizadas com o auxílio do software Autodesk Robot Structural Analysis (ARSA), considerando verificações de Estado Limite Último (ELU) e Estado Limite de Serviço (ELS), conforme os critérios estabelecidos pela NBR 8800 (ABNT, 2008). A taxa de consumo de aço foi determinada a partir da relação entre o peso da viga analisada e a área construída do galpão. Os resultados demonstraram que os modelos em vigas de alma cheia apresentaram melhor desempenho estrutural e menores taxas de consumo de aço para galpões de menores dimensões, enquanto os modelos treliçados passaram a apresentar comportamento progressivamente mais eficiente conforme o aumento dos vãos e espaçamentos longitudinais.pt
dc.description.abstractIn industrial buildings, steel portal frames, combined with secondary members such aspurlins and bracing systems, make it possible to span large distances while providinghigh structural capacity and rapid construction. In this context, the choice of thestructural system directly influences material consumption, structural performance, andconstruction costs. Therefore, this study aimed to comparatively evaluate the steel consumption rate of industrial buildings composed of portal frames with solid-webbeams and portal frames with parallel-chord truss beams, seeking to identify the most efficient solutions for different geometric configurations. Structural models with spans ranging from 12 m to 24 m and longitudinal frame spacings of 5 m, 6 m, 7 m, and 8 m were analyzed, totaling 56 models. Structural modeling and analyses were performed using Autodesk Robot Structural Analysis (ARSA), considering Ultimate Limit State (ULS) and Serviceability Limit State (SLS) verifications in accordance with the criteria established by ABNT NBR 8800:2008. The steel consumption rate was determined from the ratio between the weight of the analyzed beam and the building floor area. The results showed that the solid-web beam models exhibited better structural performance and lower steel consumption rates for smaller industrial buildings, whereas the truss beam models demonstrated progressively imen
dc.identifier.citationSOGAWA, Bruno Massao. Estudo comparativo da taxa de aço entre galpões industriais com pórticos em viga de alma cheia e pórticos em viga treliçada. Orientador: Emerson Alexandro Bolandim. 2026. Trabalho de Conclusão de Curso (Graduação em Engenharia Civil) – Universidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteira, 2026pt
dc.identifier.lattes6979355557668849
dc.identifier.urihttps://hdl.handle.net/11449/327635
dc.language.isopor
dc.publisherUniversidade Estadual Paulista (Unesp)pt
dc.rights.accessRightsAcesso abertopt
dc.subjectAnálise comparativa de pórticospt
dc.subjectTaxa de consumo de aço em galpõespt
dc.subjectOtimização de galpões metálicospt
dc.titleEstudo comparativo da taxa de aço entre galpões industriais com pórticos em viga de alma cheia e pórticos em viga treliçadapt
dc.title.alternativeComparative study of steel usage rates in industrial sheds with solid-web beam frames versus trussed beam framesen
dc.typeTrabalho de conclusão de cursopt
dspace.entity.typePublicationen
relation.isOrgUnitOfPublication85b724f4-c5d4-4984-9caf-8f0f0d076a19
relation.isOrgUnitOfPublication.latestForDiscovery85b724f4-c5d4-4984-9caf-8f0f0d076a19
relation.isUndergradCourseOfPublication5e5cbd24-5aa0-4323-a069-fb86a36ad159
relation.isUndergradCourseOfPublication.latestForDiscovery5e5cbd24-5aa0-4323-a069-fb86a36ad159
unesp.campusUniversidade Estadual Paulista (UNESP), Faculdade de Engenharia, Ilha Solteirapt
unesp.examinationboard.typeBanca públicapt
unesp.undergraduateIlha Solteira - FEIS - Engenharia Civilpt

Arquivos

Pacote original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
sogawa_bm_tcc_ilha.pdf
Tamanho:
1,89 MB
Formato:
Adobe Portable Document Format