Publicação: Electrothermal AAS determination of Ni in soft drinks using Co as the internal standard
dc.contributor.author | de Oliveira, A. P. | |
dc.contributor.author | Neto, JAG | |
dc.contributor.author | Nobrega, J. A. | |
dc.contributor.author | Oliveira, P. V. | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal de São Carlos (UFSCar) | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.date.accessioned | 2014-05-20T15:20:20Z | |
dc.date.available | 2014-05-20T15:20:20Z | |
dc.date.issued | 2005-07-01 | |
dc.description.abstract | A method for the direct determination of Ni in soft drinks by graphite furnace atomic absorption spectrometry using a transversely heated graphite atomizer (THGA), Zeeman-effect background corrector, and Co as the internal standard (IS) is proposed. Magnesium nitrate was used to stabilize both Ni and Co. All diluted samples (1+1) in 0.2% (v/v) HNO3 and reference solutions [5.0-50 mu g L-1 Ni in 0.2% (v/v) HNO3] were spiked with 50 mu g L-1 Co. For a 20-mu L sample dispensed into the atomizer, correlations between the ratio of absorbance of Ni to absorbance of Co and the analyte concentration were close to 0.9996. The relative standard deviation of the measurements varied from 0.5 to 3.4% and 1.0 to 7.0% (n=12) with and without IS, respectively. Recoveries within 98-104% for Ni spikes were obtained using IS. The characteristic mass was calculated as 43 pg Ni and the limit of detection was 1.4 mu g L-1. The accuracy of the method was checked for the direct determination of Ni in soft drinks and the results obtained with IS were better than those without IS. | en |
dc.description.affiliation | Univ Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliation | Univ Fed Sao Carlos, Dept Quim, BR-13560970 Sao Carlos, SP, Brazil | |
dc.description.affiliation | Univ São Paulo, Inst Quim, São Paulo, Brazil | |
dc.description.affiliationUnesp | Univ Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 158-161 | |
dc.identifier.citation | Atomic Spectroscopy. Shelton: Perkin-elmer Corp, v. 26, n. 4, p. 158-161, 2005. | |
dc.identifier.issn | 0195-5373 | |
dc.identifier.uri | http://hdl.handle.net/11449/31662 | |
dc.identifier.wos | WOS:000231100000005 | |
dc.language.iso | eng | |
dc.publisher | Perkin-elmer Corp | |
dc.relation.ispartof | Atomic Spectroscopy | |
dc.relation.ispartofjcr | 1.123 | |
dc.relation.ispartofsjr | 0,327 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.title | Electrothermal AAS determination of Ni in soft drinks using Co as the internal standard | en |
dc.type | Artigo | |
dcterms.rightsHolder | Perkin-elmer Corp | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: