Publicação: Flow-injection spectrophotometric determination of azithromycin in pharmaceutical formulations using p-chloranil in the presence of hydrogen peroxide
dc.contributor.author | Rufino, Jose Luiz [UNESP] | |
dc.contributor.author | Pezza, Helena Redigolo [UNESP] | |
dc.contributor.author | Pezza, Leonardo [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2014-05-20T14:19:26Z | |
dc.date.available | 2014-05-20T14:19:26Z | |
dc.date.issued | 2008-07-01 | |
dc.description.abstract | A flow-injection (FI) spectrophotometric procedure exploiting merging zones is proposed for the determination of azithromycin in pharmaceutical formulations. The method is based on the reaction of azithromycin with tetrachloro-phenzoquinone (p-chloranil) accelerated by hydrogen peroxide and conducted in a methanol medium, producing a purple-red color compound (lambda(max) = 540 nm). The FI system and the experimental conditions were optimized using a multivariate method. Beer's law is obeyed in a concentration range of 50 - 1600 mu g mL(-1) with an excellent correlation coefficient (r = 0.9998). The detection limit and the quantification limit were 6.6 and 22.1 mu g mL(-1), respectively. No interference was observed from the common excipients, and the recoveries were within 98.6 to 100.4%. The procedure was applied to the determination of azithromycin in pharmaceuticals with a high sampling rate (65 samples h(-1)). The results obtained by the proposed method were in good agreement with those obtained by the comparative method at 95% confidence level. | en |
dc.description.affiliation | São Paulo State Univ, UNESP, Inst Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.description.affiliationUnesp | São Paulo State Univ, UNESP, Inst Chem, BR-14801970 Araraquara, SP, Brazil | |
dc.format.extent | 871-876 | |
dc.identifier | http://dx.doi.org/10.2116/analsci.24.871 | |
dc.identifier.citation | Analytical Sciences. Tokyo: Japan Soc Analytical Chemistry, v. 24, n. 7, p. 871-876, 2008. | |
dc.identifier.doi | 10.2116/analsci.24.871 | |
dc.identifier.issn | 0910-6340 | |
dc.identifier.lattes | 3192125098361121 | |
dc.identifier.lattes | 5978908591853524 | |
dc.identifier.orcid | 0000-0003-0197-7369 | |
dc.identifier.uri | http://hdl.handle.net/11449/25865 | |
dc.identifier.wos | WOS:000257789800010 | |
dc.language.iso | eng | |
dc.publisher | Japan Soc Analytical Chemistry | |
dc.relation.ispartof | Analytical Sciences | |
dc.relation.ispartofjcr | 1.355 | |
dc.relation.ispartofsjr | 0,424 | |
dc.rights.accessRights | Acesso aberto | |
dc.source | Web of Science | |
dc.title | Flow-injection spectrophotometric determination of azithromycin in pharmaceutical formulations using p-chloranil in the presence of hydrogen peroxide | en |
dc.type | Artigo | |
dcterms.rightsHolder | Japan Soc Analytical Chemistry | |
dspace.entity.type | Publication | |
unesp.author.lattes | 3192125098361121 | |
unesp.author.lattes | 5978908591853524 | |
unesp.author.orcid | 0000-0003-0197-7369[3] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
unesp.department | Química Orgânica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 2 de 2
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição:
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: