Publicação: A novel citrus pectin-modified carbon paste electrochemical sensor used for copper determination in biofuel
dc.contributor.author | Alves, Gustavo Murilo [UNESP] | |
dc.contributor.author | da Silva, José Luiz [UNESP] | |
dc.contributor.author | Stradiotto, Nelson Ramos [UNESP] | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.date.accessioned | 2021-06-25T10:33:18Z | |
dc.date.available | 2021-06-25T10:33:18Z | |
dc.date.issued | 2021-02-01 | |
dc.description.abstract | This paper reports the construction of a citrus pectin-modified carbon paste electrode (PEC/CPE) which was applied for electrochemical sensitive detection of copper in biofuel. Considering its low cost of production and ease of handling, this novel sensor is a suitable alternative tool for ensuring the quality control of commercial bioethanol. Pectin carboxylic groups presence in the modified electrode helped increase its current response by 32% compared to the unmodified electrode. Under optimized conditions, using differential-pulse anodic stripping voltammetry, the analytical curve presented linear range from 5.0 × 10−8 to 1.0 × 10−4 mol L−1 (R = 0.999), with detection limit of 2.5 × 10−8 mol L−1, quantification limit of 8.3 × 10−8 mol L−1 and sensibility of 0.12 A mol−1 L. The PEC/CPE was successfully applied for copper determination in bioethanol fuel sample where recoveries ≥99% were obtained. The sensor presented good selectivity, reproducibility and repeatability (RSD ≤ 3.6%), with long-term stability over three months (RSD ≤ 6.3%). | en |
dc.description.affiliation | Analytical Chemistry Department Institute of Chemistry São Paulo State University (UNESP) | |
dc.description.affiliation | Bioenergy Research Institute São Paulo State University (UNESP) | |
dc.description.affiliationUnesp | Analytical Chemistry Department Institute of Chemistry São Paulo State University (UNESP) | |
dc.description.affiliationUnesp | Bioenergy Research Institute São Paulo State University (UNESP) | |
dc.description.sponsorship | Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) | |
dc.description.sponsorship | Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) | |
dc.description.sponsorship | Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) | |
dc.description.sponsorshipId | CNPq: 103340/2017-3 | |
dc.description.sponsorshipId | CNPq: 123150/2015-9 | |
dc.description.sponsorshipId | FAPESP: 2014/50945-4 | |
dc.description.sponsorshipId | CNPq: 408783/2018-4 | |
dc.description.sponsorshipId | CAPES: 88887.368610/2019-00 | |
dc.identifier | http://dx.doi.org/10.1016/j.measurement.2020.108356 | |
dc.identifier.citation | Measurement: Journal of the International Measurement Confederation, v. 169. | |
dc.identifier.doi | 10.1016/j.measurement.2020.108356 | |
dc.identifier.issn | 0263-2241 | |
dc.identifier.scopus | 2-s2.0-85089822021 | |
dc.identifier.uri | http://hdl.handle.net/11449/206502 | |
dc.language.iso | eng | |
dc.relation.ispartof | Measurement: Journal of the International Measurement Confederation | |
dc.source | Scopus | |
dc.subject | Bioethanol fuel | |
dc.subject | Carbon paste electrode | |
dc.subject | Citrus pectin | |
dc.subject | Copper | |
dc.subject | Polysaccharide | |
dc.subject | Stripping voltammetry | |
dc.title | A novel citrus pectin-modified carbon paste electrochemical sensor used for copper determination in biofuel | en |
dc.type | Artigo | |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |