Direct determination of phosphite in fertilizers by flow-injection amperometry

dc.contributor.authorFranzini, Vanessa Pezza
dc.contributor.authorFugivara, Cecilio Sadao [UNESP]
dc.contributor.authorBenedetti, Assis Vicente [UNESP]
dc.contributor.authorRibeiro, Clovis Augusto [UNESP]
dc.contributor.authorCavalheiro, Eder Tadeu Gomes
dc.contributor.authorGomes Neto, José Anchieta [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2014-05-20T15:27:31Z
dc.date.available2014-05-20T15:27:31Z
dc.date.issued2007-09-01
dc.description.abstractA sensor based on graphite electrode modified with palladium-platinum-palladium film is proposed for phosphite determination by flow-injection amperometry. The modified electrode was prepared by a sequential cathodic deposition of Pd, Pt and Pd on a graphite electrode from 0.5% m/v PdCl2 + 28% m/v NH4OH and 2% m/v H2PtCl6 + 10% v/v H2SO4 solutions. After suitable conditioning, the electrode showed catalytic activity for phosphite oxidation when 0. 15 V was applied. The proposed system handles approximately 50 samples per hour (0.0.1 - 0.05 mol L-1 Na-2 HPO3; R-2 = 0.9997), consuming ca. 70 mu L of sample per determination. The limit of detection and amperometric sensibility were 5 X 10(-4) mol L-1 and 1.5 mA L mol(-1), respectively. The proposed method was applied to analysis of fertilizer samples without pre-treatment. Results are in agreement with those obtained by spectrophotometry and titrimetry at 95% confidence level and good recoveries (96-109%) of spiked samples were found. Relative standard deviation (n=12) of a 0.01 mol L-1 Na2HPO3 sample was 2%. The useful lifetime of modified electrode was around 220 determinations. For routine purposes it means that this electrode can be continuously used for 5 hours.en
dc.description.affiliationUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
dc.description.affiliationUniv São Paulo, Inst Quim, BR-13560970 Sao Carlos, SP, Brazil
dc.description.affiliationUnespUniv Estadual Paulista, Dept Quim Analit, BR-14801970 Araraquara, SP, Brazil
dc.format.extent1794-1798
dc.identifierhttp://dx.doi.org/10.1002/elan.200703935
dc.identifier.citationElectroanalysis. Weinheim: Wiley-v C H Verlag Gmbh, v. 19, n. 17, p. 1794-1798, 2007.
dc.identifier.doi10.1002/elan.200703935
dc.identifier.issn1040-0397
dc.identifier.lattes2797127887030838
dc.identifier.lattes8498310891810082
dc.identifier.lattes8708735699846578
dc.identifier.orcid0000-0002-7984-5908
dc.identifier.urihttp://hdl.handle.net/11449/37472
dc.identifier.wosWOS:000249294800007
dc.language.isoeng
dc.publisherWiley-Blackwell
dc.relation.ispartofElectroanalysis
dc.relation.ispartofjcr2.851
dc.relation.ispartofsjr0,692
dc.rights.accessRightsAcesso restrito
dc.sourceWeb of Science
dc.subjectphosphitept
dc.subjectfertilizerpt
dc.subjectmodified electrodept
dc.subjectflow-injection analysispt
dc.titleDirect determination of phosphite in fertilizers by flow-injection amperometryen
dc.typeArtigo
dcterms.licensehttp://olabout.wiley.com/WileyCDA/Section/id-406071.html
dcterms.rightsHolderWiley-Blackwell
dspace.entity.typePublication
unesp.author.lattes2797127887030838[2]
unesp.author.lattes8708735699846578
unesp.author.lattes1769008264876945[3]
unesp.author.lattes8498310891810082[4]
unesp.author.orcid0000-0002-0243-6639[3]
unesp.author.orcid0000-0002-7984-5908[4]
unesp.author.orcid0000-0002-2288-2601[2]
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: