Publicação: Gold nanoelectrode ensembles for direct trace electroanalysis of iodide
dc.contributor.author | Pereira, Francisco C. | |
dc.contributor.author | Moretto, Ligia M. | |
dc.contributor.author | De Leo, Manuela | |
dc.contributor.author | Zanoni, Maria Valnice Boldrin [UNESP] | |
dc.contributor.author | Ugo, Paolo | |
dc.contributor.institution | Univ Venice | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Universidade Federal do Rio Grande do Norte (UFRN) | |
dc.date.accessioned | 2014-05-20T15:29:52Z | |
dc.date.available | 2014-05-20T15:29:52Z | |
dc.date.issued | 2006-08-04 | |
dc.description.abstract | A procedure for the standardization of ensembles of gold nanodisk electrodes (NEE) of 30 nm diameter is presented, which is based on the analytical comparison between experimental cyclic voltammograms (CV) obtained at the NEEs in diluted solutions of redox probes and CV patterns obtained by digital simulation. Possible origins of defects sometimes found in NEEs are discussed. Selected NEEs are then employed for the study of the electrochemical oxidation of iodide in acidic solutions. CV patterns display typical quasi-reversible behavior which involves associated chemical reactions between adsorbed and solution species. The main CV characteristics at the NEE compare with those observed at millimeter sized gold disk electrodes (Au-macro), apart a slight shift in E1/2 values and slightly higher peak to peak separation at the NEE. The detection limit (DC) at NEEs is 0.3 mu M, which is more than one order of magnitude lower than DL at the Au-macro (4 RM). The mechanism of the electrochemical oxidation of iodide at NEEs is discussed. Finally, NEEs are applied to the direct determination of iodide at micromolar concentration levels in real samples, namely in some ophthalmic drugs and iodized table salt. (c) 2006 Elsevier B.V. All rights reserved. | en |
dc.description.affiliation | Univ Venice, Dipartimento Chim Fis, I-30123 Venice, Italy | |
dc.description.affiliation | UNESP, Inst Chem, Dept Analyt Chem, BR-14800900 Araraquara, SP, Brazil | |
dc.description.affiliation | Univ Fed Rio Grande Norte, Dept Chem, BR-59072970 Natal, RN, Brazil | |
dc.description.affiliationUnesp | UNESP, Inst Chem, Dept Analyt Chem, BR-14800900 Araraquara, SP, Brazil | |
dc.format.extent | 16-24 | |
dc.identifier | http://dx.doi.org/10.1016/j.aca.2006.05.056 | |
dc.identifier.citation | Analytica Chimica Acta. Amsterdam: Elsevier B.V., v. 575, n. 1, p. 16-24, 2006. | |
dc.identifier.doi | 10.1016/j.aca.2006.05.056 | |
dc.identifier.issn | 0003-2670 | |
dc.identifier.orcid | 0000-0002-2296-1393 | |
dc.identifier.uri | http://hdl.handle.net/11449/39352 | |
dc.identifier.wos | WOS:000239674600003 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Analytica Chimica Acta | |
dc.relation.ispartofjcr | 5.123 | |
dc.relation.ispartofsjr | 1,512 | |
dc.rights.accessRights | Acesso restrito | |
dc.source | Web of Science | |
dc.subject | nanoelectrode ensembles | pt |
dc.subject | iodide | pt |
dc.subject | voltammetry | pt |
dc.subject | edible salt | pt |
dc.subject | ophthalmic drugs | pt |
dc.title | Gold nanoelectrode ensembles for direct trace electroanalysis of iodide | en |
dc.type | Artigo | |
dcterms.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dcterms.rightsHolder | Elsevier B.V. | |
dspace.entity.type | Publication | |
unesp.author.orcid | 0000-0002-2296-1393[4] | |
unesp.campus | Universidade Estadual Paulista (UNESP), Instituto de Química, Araraquara | pt |
unesp.department | Química Analítica - IQAR | pt |
Arquivos
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: