Publicação: Development of a low cost force platform for biomechanical parameters analysis
dc.contributor.author | Silva, Marcelo Guimarães [UNESP] | |
dc.contributor.author | Moreira, Pedro Vieira Sarmet | |
dc.contributor.author | Rocha, Henrique Martins | |
dc.contributor.institution | Universidade Estadual Paulista (Unesp) | |
dc.contributor.institution | Federal University of Rio de Janeiro | |
dc.contributor.institution | Rio de Janeiro State University | |
dc.date.accessioned | 2021-07-14T10:37:04Z | |
dc.date.available | 2021-07-14T10:37:04Z | |
dc.date.issued | 2017-09-12 | |
dc.description.abstract | AbstractIntroduction: The maintenance of balance and body orientation during standing is essential to perform different activities. One of the devices used to measure balance them is the force platform. This device measures the ground reaction force (GRF) and displacement of the center of pressure (COP), both biomechanical parameters involved in human motion. This article proposes a new design for non-commercial low-cost force platforms for scientific research purposes. Methods for calibration and validation are also described. | en |
dc.description.affiliation | São Paulo State University, Faculty of Engineering of Guaratinguetá | |
dc.description.affiliation | Federal University of Rio de Janeiro, Biomedical Engineering Program | |
dc.description.affiliation | Rio de Janeiro State University, Faculty of Technology | |
dc.description.affiliationUnesp | São Paulo State University, Faculty of Engineering of Guaratinguetá | |
dc.format.extent | 259-268 | |
dc.identifier | http://dx.doi.org/10.1590/2446-4740.01217 | |
dc.identifier.citation | Research on Biomedical Engineering. Sociedade Brasileira de Engenharia Biomédica, v. 33, n. 3, p. 259-268, 2017. | |
dc.identifier.doi | 10.1590/2446-4740.01217 | |
dc.identifier.file | S2446-47402017000300259.pdf | |
dc.identifier.issn | 2446-4732 | |
dc.identifier.issn | 2446-4740 | |
dc.identifier.scielo | S2446-47402017000300259 | |
dc.identifier.uri | http://hdl.handle.net/11449/212255 | |
dc.language.iso | eng | |
dc.publisher | Sociedade Brasileira de Engenharia Biomédica | |
dc.relation.ispartof | Research on Biomedical Engineering | |
dc.rights.accessRights | Acesso aberto | pt |
dc.source | SciELO | |
dc.subject | Force platform | en |
dc.subject | Biomechanical parameters | en |
dc.subject | Low-cost development | en |
dc.subject | Ground-reaction force | en |
dc.subject | COP displacement | en |
dc.title | Development of a low cost force platform for biomechanical parameters analysis | en |
dc.type | Artigo | pt |
dspace.entity.type | Publication | |
unesp.campus | Universidade Estadual Paulista (UNESP), Faculdade de Engenharia e Ciências, Guaratinguetá | pt |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S2446-47402017000300259.pdf
- Tamanho:
- 1.47 MB
- Formato:
- Adobe Portable Document Format