Logotipo do repositório
 

Publicação:
Measurements of ambient ozone using indigo blue-coated filters

dc.contributor.authorFelix, Erika P. [UNESP]
dc.contributor.authorDe Souza, Karina A. D. [UNESP]
dc.contributor.authorDias, Cristine M. [UNESP]
dc.contributor.authorCardoso, Arnaldo A. [UNESP]
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.date.accessioned2022-04-28T20:07:44Z
dc.date.available2022-04-28T20:07:44Z
dc.date.issued2006-12-01
dc.description.abstractOzone monitoring techniques utilize expensive instruments that are often large and heavy. These instruments are not easy to handle in the field, and their size also limits some sampling schemes, principally for indoor ozone determination. We have developed a lightweight, inexpensive, and sensitive method that offers flexibility to undertake measurements of ambient ozone in many environments, both indoor and outdoor. The method is based on the reaction of ozone with indigo blue dye. The indigo molecule contains 1 carbon double bond (C = C) that reacts with ozone and results in nearly colorless reaction products. During sample collection, 2 cellulose filters coated with 40 μL of 1.0 × 10-3 M indigo blue were used. The determinations were done spectrophotometrically at 250 and 600 nm. The analytical parameters studied were sampling time and flow rate. Analytical curves were constructed with concentrations ranging from 37 to 123 parts per billion by volume (ppbv) of standard ozone, at 0.4 L/min and 15 min sampling time. The detection limits achieved were 6 and 9 ppbv, respectively, at 250 and 600 nm. Considering interferences, measurements made at 250 nm gave more reliable and specific values for ozone.en
dc.description.affiliationUniversidade Estadual Paulista (São Paulo State University) Institute of Chemistry Department of Analytical Chemistry, CP 355, CEP 14801-970, Araraquara, SP
dc.description.affiliationUnespUniversidade Estadual Paulista (São Paulo State University) Institute of Chemistry Department of Analytical Chemistry, CP 355, CEP 14801-970, Araraquara, SP
dc.format.extent480-485
dc.identifier.citationJournal of AOAC International, v. 89, n. 2, p. 480-485, 2006.
dc.identifier.issn1060-3271
dc.identifier.scopus2-s2.0-33646840629
dc.identifier.urihttp://hdl.handle.net/11449/224758
dc.language.isoeng
dc.relation.ispartofJournal of AOAC International
dc.sourceScopus
dc.titleMeasurements of ambient ozone using indigo blue-coated filtersen
dc.typeArtigo
dspace.entity.typePublication
unesp.campusUniversidade Estadual Paulista (UNESP), Instituto de Química, Araraquarapt
unesp.departmentQuímica Analítica - IQARpt

Arquivos