Logotipo do repositório

Addition of Nickel by the Watts Bath as a Way to Correct the Phase Balance on Nd:YAG Pulsed-Laser-Welded UNS S32750

dc.contributor.authorda Cruz Junior, Eli J.
dc.contributor.authorSeloto, Bruna B. [UNESP]
dc.contributor.authorVentrella, Vicente A. [UNESP]
dc.contributor.authorSettimi, Alessio G.
dc.contributor.authorGennari, Claudio
dc.contributor.authorCalliari, Irene
dc.contributor.authorZambon, Andrea
dc.contributor.institutionScience and Technology of São Paulo
dc.contributor.institutionUniversidade Estadual Paulista (UNESP)
dc.contributor.institutionUniversity of Padua
dc.date.accessioned2022-04-29T08:36:13Z
dc.date.available2022-04-29T08:36:13Z
dc.date.issued2022-01-01
dc.description.abstractObtaining a balanced microstructure in the fusion zone on a super duplex stainless steel (SDSS) weld is a challenge. The present work reports the use of the Watts bath to correct the phase balance on laser-welded SDSS. Three different Watts bath times were used, and the microstructure of the weld bead was evaluated. The Watts bath was efficient to correct the undesirable unbalanced microstructure resulting from SDSS laser welding as the austenite percentage increased.en
dc.description.affiliationFederal Institute of Education Science and Technology of São Paulo, Campus Itapetininga, Av. João Olímpio de Oliveira 1561
dc.description.affiliationMechanical Engineering Department UNESP São Paulo State University, Campus of Ilha Solteira, Av. Brasil 56
dc.description.affiliationDepartment of Industrial Engineering University of Padua, Via Gradenigo, 6/a
dc.description.affiliationUnespMechanical Engineering Department UNESP São Paulo State University, Campus of Ilha Solteira, Av. Brasil 56
dc.format.extent25-28
dc.identifierhttp://dx.doi.org/10.1007/s11661-021-06521-0
dc.identifier.citationMetallurgical and Materials Transactions A: Physical Metallurgy and Materials Science, v. 53, n. 1, p. 25-28, 2022.
dc.identifier.dimensionspub.1142418284
dc.identifier.doi10.1007/s11661-021-06521-0
dc.identifier.issn1073-5623
dc.identifier.issn1543-1940
dc.identifier.orcid0000-0003-0865-5258
dc.identifier.orcid0000-0003-0913-6265
dc.identifier.orcid0000-0002-1576-3532
dc.identifier.orcid0000-0002-8059-7876
dc.identifier.orcid0000-0002-6668-3866
dc.identifier.scopus2-s2.0-85118592481
dc.identifier.urihttp://hdl.handle.net/11449/229844
dc.language.isoeng
dc.publisherSpringer Nature
dc.relation.ispartofMetallurgical and Materials Transactions A: Physical Metallurgy and Materials Science
dc.rights.accessRightsAcesso abertopt
dc.rights.sourceRightsoa_all
dc.rights.sourceRightsgreen
dc.sourceScopus
dc.sourceDimensions
dc.titleAddition of Nickel by the Watts Bath as a Way to Correct the Phase Balance on Nd:YAG Pulsed-Laser-Welded UNS S32750en
dc.typeArtigopt
dspace.entity.typePublication
unesp.departmentEngenharia Mecânica - FEISpt

Arquivos