Switched optimal robust control of a 3-DOF helicopter subject to a critical fault
Nenhuma Miniatura disponível
Data
2016-01-01
Autores
Assuncao, Edvaldo [UNESP]
Teixeira, Marcelo C. M. [UNESP]
Buzachero, Luiz F. S.
Silva, Emerson R. P. da
IEEE
Título da Revista
ISSN da Revista
Título de Volume
Editor
Ieee
Resumo
This paper proposes an improved technique for the stabilization of continuous-time, switched controlled linear systems with decay rate performance index and optimization of the controller's norm. This technique is of closed loop nature (trajectory dependent) and is designed from the solution of Lyapunov-Metzler inequalities from which the stability condition (including chattering) is expressed. The performance index used here is the decay rate that aims to reduce the system's settling time. The other important tool used is the optimization of the controller's norm that aims to reduce the gains and facilitate its application. A practical implementation of the improved technique was made in a Quanser's 3-DOF helicopter subject to a structural fault in the back engine, which was addressed as a polytopic time-varying uncertainty.
Descrição
Palavras-chave
switched linear systems, robust control, decay rate, optimization, critical fault
Como citar