Effect of post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins

Carregando...
Imagem de Miniatura

Data

2006-08-31

Autores

Jorge, Janaina Habib [UNESP]
Giampaolo, Eunice Teresinha [UNESP]
Vergani, Carlos Eduardo [UNESP]
Machado, Ana Lucia [UNESP]
Pavarina, Ana Claudia [UNESP]
Carlos, Iracilda Zeppone [UNESP]

Título da Revista

ISSN da Revista

Título de Volume

Editor

Resumo

Introduction: Most denture base acrylic resins have polymethylmethacrylate in their composition. Several authors have discussed the polymerization process involved in converting monomer into polymer because adequate polymerization is a crucial factor in optimizing the physical properties and biocompatibility of denture base acrylic resins. To ensure the safety of these materials, in vitro cytotoxicity assays have been developed as preliminary screening tests to evaluate material biocompatibility. 3H-thymidine incorporation test, which measures the number of cells synthesizing DNA, is one of the biological assays suggested for cytotoxicity testing. Aim: The purpose of this study was to investigate, using 3H-thymidine incorporation test, the effect of microwave and water-bath post-polymerization heat treatments on the cytotoxicity of two denture base acrylic resins. Materials and Methods: Nine disc-shaped specimens (10 x 1 mm) of each denture base resin (Lucitone 550 and QC 20) were prepared according to the manufacturers' recommendations and stored in distilled water at 37°C for 48 h. The specimens were assigned to 3 groups: 1) post-polymerization in a microwave oven for 3 min at 500 W; 2) post-polymerization in water-bath at 55°C for 60 min; and 3) without post-polymerization. For preparation of eluates, 3 discs were placed into a sterile glass vial with 9 mL of Eagle's medium and incubated at 37°C for 24 h. The cytotoxic effect of the eluates was evaluated by 3H-thymidine incorporation. Results: The results showed that the components leached from the resins were cytotoxic to L929 cells, except for the specimens heat treated in water bath (p<0.05). Compared to the group with no heat treatment, water-bath decreased the cytotoxicity of the denture base acrylic resins. Conclusion: The in vitro cytotoxicity of the tested denture base materials was not influenced by microwave post-polymerization heat treatment.

Descrição

Palavras-chave

Cell culture, Cytotoxicity, Denture base resins

Como citar

Journal of Applied Oral Science, v. 14, n. 3, p. 203-207, 2006.