SIGNALS GENERATED BY A SENSOR THAT CAPTURES THE CANTILEVER DEFLECTION OF THE ATOMIC FORCE MICROSCOPE WITH NONLINEAR BEHAVIOR

dc.contributor.authorNozaki, Ricardo
dc.contributor.authorNavarro, Helio A.
dc.contributor.authorBrasil, Reyolando
dc.contributor.authorPereira da Silva, Marcelo A.
dc.contributor.authorTusset, Angelo M.
dc.contributor.authorBueno, Atila M. [UNESP]
dc.contributor.authorBalthazar, Jose M. [UNESP]
dc.contributor.authorASME
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.contributor.institutionUniversidade Federal do ABC (UFABC)
dc.contributor.institutionCent Univ Paulista
dc.contributor.institutionFed Technol Univ Parana
dc.contributor.institutionUniversidade Estadual Paulista (Unesp)
dc.date.accessioned2018-11-27T16:55:49Z
dc.date.available2018-11-27T16:55:49Z
dc.date.issued2015-01-01
dc.description.abstractThis paper presents results obtained numerically by an experimental approach. The sensor of the atomic force microscope generated cantilever deflections series that were recorded in data files as a function of time and as a function of tip-sample distance. With these series of deflections, we attempted to adjust parameters and refine models of classical oscillators atomic force microscope, making them more sensitive to tip-sample distance, through the method of system identification proposed by [12]. This method allows us to choose any model and, through its analytical solution, compare the results obtained with the experiment. The reconstruction of the state space is done with the intention of observing different phase portraits for different distances between sample-tip.en
dc.description.affiliationUniv Sao Paulo, Sao Carlos, SP, Brazil
dc.description.affiliationFed Univ ABC, Santo Andre, Brazil
dc.description.affiliationCent Univ Paulista, Sao Carlos, SP, Brazil
dc.description.affiliationFed Technol Univ Parana, Ponta Grosse, Brazil
dc.description.affiliationUNESP Sorocaba, Sorocaba, Brazil
dc.description.affiliationUNESP Bauru, Bauru, Brazil
dc.description.affiliationUnespUNESP Sorocaba, Sorocaba, Brazil
dc.description.affiliationUnespUNESP Bauru, Bauru, Brazil
dc.format.extent7
dc.identifier.citationProceedings Of The Asme International Mechanical Engineering Congress And Exposition, 2014, Vol 4a. New York: Amer Soc Mechanical Engineers, 7 p., 2015.
dc.identifier.urihttp://hdl.handle.net/11449/165229
dc.identifier.wosWOS:000379450800046
dc.language.isoeng
dc.publisherAmer Soc Mechanical Engineers
dc.relation.ispartofProceedings Of The Asme International Mechanical Engineering Congress And Exposition, 2014, Vol 4a
dc.rights.accessRightsAcesso aberto
dc.sourceWeb of Science
dc.titleSIGNALS GENERATED BY A SENSOR THAT CAPTURES THE CANTILEVER DEFLECTION OF THE ATOMIC FORCE MICROSCOPE WITH NONLINEAR BEHAVIORen
dc.typeTrabalho apresentado em evento
dcterms.rightsHolderAmer Soc Mechanical Engineers
unesp.author.lattes7416585768192991[6]
unesp.author.orcid0000-0002-1113-3330[6]

Arquivos